Chang Sheng CS9914AX | Programmable precision | Hipot Tester | Production line Test Analyzer | High voltage source

Chang Sheng CS9914AX | Programmable precision | Hipot Tester | Production line Test Analyzer | High voltage source

11400 CNY (1659.88USD)

add to cart

Product parameters:

  • Customized processing: no
  • Type: digital voltage measuring devices
  • Brand: Chang Sheng
  • Model: CS9914AX
  • Measuring range: 0.050kV~ 5.000kV
  • Input voltage: 220
  • Output voltage: 0.050kV~ 5.000kV
  • Ambient temperature: see
  • Weight: see
  • Overall dimensions: see
  • Voltage measuring error: ± (2% read value +5V)




Chang Sheng CS9914AX programmable precision voltage Tester test Analyzer production line high voltage source

CS9914AX/9914BX is the safety industry's first precision variable frequency withstand voltage Tester, the output AC voltage frequency range 40-400Hz resolution 0.1Hz . Hardware output voltage feedback high speed MCU Control, output voltage regulator range 1%Or less, making it not only can be used as a voltage tester to use, and can be used as inverter high voltage source. Normal output mode output mode and gradient so that it can be used as a production line for inspection of high voltage testing device, and can also make it as an Analyzer. Maximum transformer capacity is 500VA,To meet the UL1004In the 23.4.2The transformer capacity requirements.

Performance characteristics:

1, 240*64 drawing mode LCD display, user-friendly interface design is easy to operate.

2, which is in the English interface, you can meet the different needs of different users.

3, constant voltage output: output voltage regulation in the range ± 1%, avoid the input supply voltage is not stable and load changes in the output voltage changes, measurement results are not accurate.

4, with rapid discharge function, measuring instrument in DC after testing within 0.2s to be tested and the loop ended to ensure operator safety.

5, with DC test open circuit detection can prevent DC test because the test off miscarriages.

6, zero startup may prevent damage from being tested.

7, voltage gradient goes up, looking for analysis of breakdown point.

8, the current upper limit lower limit alarm and alarm functions can be set to prevent the test line off miscarriages.

9, and the current offset function eliminates leakage current influence on the test results of the test fixture.

10 in the testing process, you can manually change the size of the output voltage.

11, with real current measurement function.

12, with ARC detection test.

13, have GFI protection.

14, can be pre-set save the test parameters: set 30 files, each file can be set to 99 test step.

15, keypad lock, protection test parameters are not modified by operators.

16, front panel software calibration, calibration can be carried out without opening arguments.

17, PLC interface standard, optional RS232C, RS485, USB and GPIB interface.

Model

CS9914AX

CS9914BX

ACW

Output voltage

Range

0.050kV~ 5.000kV

Precision

± (2% read value +5V)

Resolution

1V

Maximum output power

500VA (5.000kV/100mA)

Maximum rated current

100mA

Minimum current range

0~ 100mA,0= no lower limit judgment

Current gear

200uA, 2mA, 20mA, 100mA

Output waveform

Sine wave

Output waveform distortion

≤ 2% (no load or pure resistance load)

Crest factor

1.3~ 1.5

Type of output signal

DDS+ amplifier

Voltage rise time

0.3s~ 999.9s 0 = voltage rise time

Test time

0.3s~ 999.9s 0 = continuous testing

Voltage drops

0.3s~ 999.9s 0 = voltage drop time

Interval time

0.0s~ 999.9s 0 = interval time

Output voltage mode

N model, g-mode

DCW

Output voltage

Range

-

0.050kV~ 6.000kV

Precision

-

± (2% read value +5V)

Resolution

-

1V

Maximum output power

-

300W (6.000kV/50mA)

Maximum rated current

-

50mA

Current gear

2uA, 20uA, 200uA, 2mA, 20mA, 50mA

Ripple

-

Less than 5%

Discharge time

-

≤200ms

Maximum charge current

-

50mA

Voltage rise time

0.3s~ 999.9s 0 = voltage rise time (except CS9914AX)

Test time

0.3s~ 999.9s 0 = continuous testing (except CS9914AX)

Voltage drops

0.3s~ 999.9s time 0 = voltage drop off (except for CS9914AX)

Interval time

0.3s~ 999.9s 0 = interval time (except CS9914AX)

Delay alarm time

0.0s~ 999.9s 0 = delay alarm time off (except for CS9914AX)

Output voltage mode

N model, g-mode

Voltage meter

Range

AC

0.050kV~ 5.000kV

DC

0.050kV~ 6.000kV

Precision

± (2% read value +5V)

Resolution

1V

Show values

Root mean square value

Ammeter

Measuring range

AC

0 ~ 100mA

0 ~ 100mA

DC

---

0 ~ 50mA

Resolution

AC

200uA files: 0.1uA, 2mA: 1uA, 20mA, 100mA: 10uA

DC

2uA files: 0.001uA, 20uA file: 0.01uA,200uA files: 0.1uA, 2mA files: 1uA,20mA, 50mA: 10uA

Measurement accuracy

2mA to ± (2%+5 characters), ﹤ 2mA ± (3%+5 characters)

Offset function

The current testing lines and accessories can be subtracted.

Test mode

GND models: RETURN Terminal chassis FLOAT mode: RETURN-end case

Timer

Range

0~ 999.9s

Resolution

0.1s

Precision

± (0.1%+50ms)