Product parameters:
Changsheng CS9914BX program - controlled precision pressure tester production line test analyzer high - pressure source
CS9914AX / 9914BX is the industry's first precision variable frequency voltage tester, the output AC voltage frequency range of 40-400Hz, a resolution of 0.1Hz . The output voltage adopts hardware feedback and high-speed MCU control technology, and the output voltage regulation rate is within 1%, it can not only be used as a voltage tester, but also can be used as a variable frequency high voltage source.Normal output mode and gradient output mode Making it as a production line with the pressure tester, but also can make it for the use of the analyzer.Transformer capacity of up to 500VA, to meet the UL1004 in 23.4.2 of the transformer capacity requirements.
Performance characteristics:
1, using 240 * 64 graphics-type LCD display, user-friendly interface design easy to operate.
2, with Chinese and English display interface, to meet the different needs of different users.
3, constant voltage output: the output voltage regulation in the ± 1% range, to avoid instability due to input power supply voltage and load changes caused by changes in output voltage, the measurement results are not accurate.
4, with a rapid discharge function, the tester can be 0.2s in the DC test time to complete the test body and circuit in the discharge, to ensure the safety of the operator.
5, with a DC test open-circuit detection function, to prevent the DC test due to loss of test line caused by miscarriage of justice.
6, zero-start to prevent the test pieces are damaged.
7, the voltage rise by time gradient, looking for breakdown point analysis.
8, can set the upper limit alarm and lower limit alarm function to prevent the test line fall off caused by miscarriage of justice.
9, the current offset function can eliminate the test fixture leakage current on the test results.
10, the test process, you can manually change the size of the output voltage.
11, with real current measurement.
12, with arc detection test function.
13, with GFI protection.
14, can be set up to save test parameters: can be set to 30 files, each file can be set to 99 test steps.
15, with the keyboard lock, protection test parameters are not modified by the operator.
16, the front panel software calibration, do not open the parameters can be calibrated.
17, standard PLC interface, optional RS232C, RS485, USB, GPIB interface.
model | CS9914AX | CS9914BX | |||||
ACW | The output voltage | range | 0.050 kV to 5.000 kV | ||||
Precision | ± (2% of reading + 5V) | ||||||
Resolution | 1V | ||||||
Maximum output power | 500VA (5.000kV / 100mA) | ||||||
Maximum rated current | 100 mA | ||||||
Lower limit current range | 0 to 100mA, 0 = No judgment lower limit | ||||||
Current range | 200 mA, 2 mA, 20 mA, 100 mA | ||||||
Output waveform | Sine wave | ||||||
Output waveform distortion | ≤2% (no load or pure resistive load) | ||||||
Crest factor | 1.3~ 1.5 | ||||||
Output signal type | DDS + power amplifier | ||||||
Voltage rise time | 0.3s ~ 999.9s 0 = voltage rise time off | ||||||
testing time | 0.3s ~ 999.9s 0 = continuous testing | ||||||
Voltage drop time | 0.3s ~ 999.9s 0 = voltage drop time off | ||||||
Intervals | 0.0s to 999.9s 0 = Interval time off | ||||||
Output voltage mode | N mode and G mode | ||||||
DCW | The output voltage | range | - | 0.050 kV to 6.000 kV | |||
Precision | - | ± (2% of reading + 5V) | |||||
Resolution | - | 1V | |||||
Maximum output power | - | 300W (6.000 kV / 50 mA) | |||||
Maximum rated current | - | 50mA | |||||
Current range | 2uA, 20uA, 200uA, 2mA, 20mA, 50mA | ||||||
Ripple factor | - | ≤5% | |||||
Discharge time | - | Lt; | |||||
Maximum charge current | - | 50mA | |||||
Voltage rise time | 0.3s to 999.9s 0 = Voltage rise time off (except CS9914AX) | ||||||
testing time | 0.3s ~ 999.9s 0 = continuous testing (except CS9914AX) | ||||||
Voltage drop time | 0.3s to 999.9s 0 = Voltage fall time off (except CS9914AX) | ||||||
Intervals | 0.3s to 999.9s 0 = Interval time off (except CS9914AX) | ||||||
Delayed alarm time | 0.0s to 999.9s 0 = Delayed alarm time off (except CS9914AX) | ||||||
Output voltage mode | N mode and G mode | ||||||
Electricity Pressure table | range | AC | 0.050 kV to 5.000 kV | ||||
DC |
| 0.050 kV to 6.000 kV | |||||
Precision | ± (2% of reading + 5V) | ||||||
Resolution | 1V | ||||||
Displays the value | Root mean square value | ||||||
Electricity flow table | Measuring range | AC | 0 to 100 mA | 0 to 100 mA | |||
DC | --- | 0 to 50 mA | |||||
Resolution | AC | 200uA file: 0.1uA, 2mA file: 1uA, 20mA, 100mA file: 10uA | |||||
DC | 2uA file: 0.001uA, 20uA file: 0.01uA, 200uA file: 0.1uA, 2mA file: 1uA, 20mA, 50mA file: 10uA | ||||||
measurement accuracy | ≥ 2mA for ± (2% + 5 words), <2mA for ± (3% + 5 words) | ||||||
Offset function | The current in the test leads and accessories can be subtracted. | ||||||
Test mode | GND mode: RETURN Termination housing FLOAT mode: RETURN terminal not connected to the chassis | ||||||
meter Time Device | range | 0~ 999.9s | |||||
Resolution | 0.1s | ||||||
Precision | ± (0.1% + 50ms) | ||||||