Nanjing Chang Sheng CS9912BS | PV | Voltage testers | New products | Comprehensive safety measurements

Nanjing Chang Sheng CS9912BS | PV | Voltage testers | New products | Comprehensive safety measurements

7500 CNY (1092.02USD)

add to cart

Product parameters:

  • Customized processing: no
  • Type: PV voltage Tester
  • Brand: Chang Sheng
  • Model: CS9912BS
  • Measuring range: (0.050~ 6.000) kV
  • Input voltage: 220
  • Output voltage: (0.050~ 6.000) kV
  • Ambient temperature: see
  • Weight: see
  • Overall dimensions: see
  • Voltage measuring error: ± (2% read value +5V)




Changsheng new CS9912BS PV voltage Tester

This series program resistance pressure test instrument are used high-speed MCU and mass digital circuit design of high performance of Ann rules test instrument, its output voltage of size, output voltage of rose, declined, output voltage of frequency completely by MCU control, can real-time displayed breakdown current value and voltage value, and has soft body calibration function, equipped with PLC interface, RS232C, and can matching RS485 interface, USB device, USB Host, GPIB, Can be easily with computer or PLC integrated test system. The ability to quickly and accurately to household appliances, instruments, lighting, electric heating appliance, computer, information safety integrated measurement machine.

Performance characteristics:

AC/DC voltage function
Using DDS digital signal synthesis technology produces precise, stable, clean, low-distortion sine wave
Adjustable pressure rise and fall time, adapt to different test requirements
ARC detection has two ways to select: current grade
Test results can be simultaneously saved in support of detailed statistical operations
With dual-band integrated testing, frequency 50 Hz, 60 Hz
Humanized operation interface, supported direct input keypad, dial input operation is simple
Complete operation helpful hints, which can effectively improve user efficiency
Testing steps, system status information displayed, for testing to learn about details of the test steps and the system state.
Supports character input type file name, file name up to 12 characters in length
Bilingual interface, meet the needs of different users
Supports mass storage, can support up to 50 (file) *40 (testing), 25*80, 10*200, 5*400 file organization format, suitable for different application testing requirements
Model
CS9911AS
CS9911BS
CS9912AS
CS9912BS
ACW
Output voltage
Range
(0.050~ 5.000)kV
Precision
± (2% read value +5V)
Resolution
1V
Maximum output power
75W
100W
Maximum rated current
15mA
20mA
Current gear
2mA, 15mA
2mA, 20mA
Current limit
(0~ 15.00) lower limit mA,0= judgement
(0~ 20.00) lower limit mA,0= judgement
Output waveform
Sine wave
Output waveform distortion
≤ 2% (no load or pure resistance load)
Crest factor
1.3~ 1.5
Output waveform
DDS+ linear power amplifier
ACW
Voltage rise time
0.3s~ 999.9s 0 = voltage rise time
Test time
0.3s~ 999.9s 0 = continuous testing
Voltage drops
0.3s~ 999.9s 0 = voltage drop time
Interval time
0.3s~ 999.9s 0 = interval time
DCW
Output voltage
Range
(0.050~ 6.000)kV
(0.050~ 6.000)kV
Precision
± (2% read value +5V)
± (2% read value +5V)
Resolution
1V
1V
Maximum output power
30W
60W
Maximum rated current
5.000mA
9.999mA
Current gear
2mA, 5mA
2mA, 10mA
Current limit
(0~ 5.000) lower limit mA,0= judgement
(0~ 9.999) lower limit mA,0= judgement
Ripple
≤5% (6kV/5mA)
≤5% (6kV/10mA)
Discharge time
≤200ms
≤200ms
Maximum charge current 5mA
9.999mA
Voltage rise time 0.3~ 999.9s 0 = voltage rise time
0.3~ 999.9s 0 = voltage rise time
Test time 0.3~ 999.9s 0 = continuous testing
0.3~ 999.9s 0 = continuous testing
Voltage drops 0.3~ 999.9s 0 = voltage drop time
0.3~ 999.9s 0 = voltage drop time
Interval time 0.3~ 999.9s 0 = interval time
0.3~ 999.9s 0 = interval time
Electricity
Pressure
Table
Range
0.050kV~ 6.000kV
Precision
± (2% read value +5V)
Resolution
1V
Show values
Root mean square value
Electricity
Flow
Table
Measuring range
AC
0 ~ 20mA
DC
0 ~ 10mA
Resolution
AC
2mA files: 1uA,20 (15mA) mA, 10uA
DC
2mA files 1uA,10 (5mA) mA, 10uA
Precision
± (2%+5 characters)
Offset current
0 ~ 2mA
Timer
Range
0.1s~ 999.9s
Accuracy/resolution
±1%/0.1s