Product parameters:
Nanjing Changsheng CS9912AN Programmable Insulation Withstand Voltage Tester
CS99N series of program-controlled security tester is the fifth generation of R & D products, customer satisfaction as the goal and special research and development. Exquisite simplicity, durable and practical as the main features of the voltage manual, automatic dual control measurement function, with U disk upgrade Function, it is a variety of production lines and test essential electrical safety tester, can quickly and accurately measure the electronic components, household appliances, insulation materials, instrumentation, lighting appliances, electric heating appliances safety regulations of the test.
Performance characteristics:
◆ Standard standard measurement system (ACW / DCW / IR / GR)
◆ standard preventive safety system (with OK lights, zero-start,
◆ high-pressure indicator, voltage safety column function)
◆ fast voltage rise time (100ms or less)
◆ Measurement of automatic stability control system
◆ can test resistance, capacitive, inductive and other different load
◆ 0.2 seconds fast discharge function
◆ Set the voltage rise time, test time, pause time
◆ With arc detection function, can set the arc detection level
◆ 20 memory groups, each with 8 test steps
◆ Multi-step test, can automatically cycle test, but also single-step manual
◆ test, for different parts of different pressure requirements of the test
◆ The number of times to start reset is recorded to prevent missing test and new test statistic function
◆ 50Hz, 60 Hz frequency selectable
◆ Standard PLC interface, optional RS232 interface, RS485 interface, U disk storage power
model | CS9911AN | CS9911BN | CS9912AN | CS9912BN | ||
ACW
| The output voltage | range | 0.200 kV to 5.000 kV | |||
Precision | ± (2% of reading + 5V) | |||||
Resolution | 1V | |||||
Maximum output power | 60VA (5.000 kV / 12mA) | 100VA (5.000 kV / 20 mA) | ||||
Maximum rated current | 12 mA | 20 mA | ||||
Lower limit current range | 0 to 12mA, 0 = No judgment lower limit | 0 to 20mA, 0 = No judgment lower limit | ||||
Current range | 2mA, 12mA | 2mA, 20mA | ||||
Output waveform | Sine wave | |||||
Output waveform distortion | ≤2% (no load or pure resistive load) | |||||
Crest factor | 1.3~ 1.5 | |||||
Output signal type | DDS + power amplifier | |||||
Voltage rise time | 0.3s ~ 999.9s 0 = voltage rise time off | |||||
testing time | 0.3s ~ 999.9s 0 = continuous testing | |||||
Intervals | 0.0s to 999.9s 0 = Interval time off | |||||
Output voltage frequency | 50Hz, 60Hz optional | |||||
Arc detection | 0 ~ 9, 0 is off | |||||
DCW
| The output voltage | range | - | 0.200 kV to 6.000 kV | - | 0.200 kV to 6.000 kV |
Precision | - | ± (2% of reading + 5V) | - | ± (2% of reading + 5V) | ||
Resolution | - | 1V | - | 1V | ||
Maximum output power | - | 30W (6.000 kV / 5 mA) | - | 60W (6.000 kV / 10 mA) | ||
Maximum rated current | - | 5mA | - | 10mA | ||
Current range | 2mA, 5mA | - | 2mA, 10mA | |||
Ripple factor | - | ≤5% | - | ≤5% | ||
Discharge time | - | Lt; | - | Lt; | ||
Maximum charge current | - | 5mA | - | 10mA | ||
Voltage rise time | - | 0.3s to 999.9s0 = voltage Rise time off | - | 0.3s ~ 999.9s0 = voltage rise time off | ||
testing time | - | 0.3s ~ 999.9s0 = continuous testing | - | 0.3s ~ 999.9s0 = continuous testing | ||
Intervals | - | 0.0s to 999.9s0 = Interval time off | - | 0.0s to 999.9s0 = Interval time off | ||
Arc detection | - | 0 ~ 9, 0 is off | - | 0 ~ 9, 0 is off | ||
Memory group | 20 | |||||
Test step | 8 | |||||