Fluke Fluke2042 cable detector line-Finder F2042 hand-held check line

Fluke Fluke2042 cable detector line-Finder F2042 hand-held check line

4200 CNY (611.54USD)

add to cart

Product parameters:

  • Customized processing: no
  • Brand: FLUKE/fluke
  • Model: Fluke2042


Fluke 2042 cable detector is a portable, hand-held instrument, used to track hidden in the wall line, locate cable faults and short circuit, electrical outlets and circuit breaker is associated, as well as tracing underground cables. Whether it is residential or commercial applications, Fluke 2042 will be for the new electrical installation installation and troubleshooting of existing device saves time and manpower. Fluke 2042 cable detector is a tool you need. • Big display, article-like figure and backlight function • automatically and manual sensitivity regulation • audio indicates • plus flashing led • automatically close function • CAT III 300 v • including of component: Fu Peter grams cable received device, Fu Peter grams cable sent device, 4 root test line, 2 a test probe, 2 a crocodile clip, work by needed of all battery • find wall in the of wire • find cable in the of short-circuit and break points • detection and circuit breaker device connected of electrical leads line • track underground cable • detection to warm in the of short-circuit · Trace metal water pipe and warm gas pipeline
Technical specifications

      Sent device output signal: 125 kHz external voltage detection voltage range: 12 to 400 v frequency range: 0 to 60 Hz display: LCD, with function displayed external voltage detection: maximum make/DC 400 v had pressure category: CAT III 300 v pollution grade: 2 power: 6x1.5 v, IEC LR6 power: maximum 40 mA fuse: f 0.5 a, 500 v, 6 a 3x32 mm temperature range : Working: 0 ° c to 40 ° c, maximum 80% relative humidity (non-condensing) storage:-20 ° c to +60 ° c, maximum 80% relative humidity (non-condensing) altitude: 2000 m the largest size (h x w x d): 190 mmx85 mmx50 mm weight: without battery: about 260 g including battery: approximately 400 g

      Received device track depth: track depth depends on media and the specific application cable positioning mode: single very application: about 0 to 2 m double very application: about 0 to 0.5 m voltage detection: about 0 to 0.4 m display: LCD, function displayed and article-like Figure power: 1x9 v, IEC 6LR61 power: no backlight or led: about 17 mA using backlight: about 50 mA using backlight and led: about 70 mA temperature range: work: 0 ° c to 40 ° c, maximum 80% Relative humidity (non-condensing). Storage:-20 ° c to +60 ° c, maximum 80% relative humidity (non-condensing). Altitude: 2000 m the largest size (height x width x depth): 250 mmx65 mmx45 mm weight: without battery: approx 220 g including batteries: approximately 270 g warranty: 2 years

    Includes Fluke cable locator transmitter fluke cable detector receiver 4 test leads 9V battery, IEC 6LR61 6 1.5 v batteries, IEC LR6 2 Alligator Clip pouch 2 test probe user manual

Ordering information Fluke 2042T Fluke 2042 cable detector spare/extra transmitter

Application of voltage

Often not labeled on the circuit of the old system. In order to avoid accidentally power off the error, it must correctly correspond to the safety device and the corresponding circuit. 2042Cable detector can also be used for this. Direct the signal transmitter is connected between phase and neutral lines. In this case, signal detection strength generally decreases. AC voltage and the electric flux signal transmitter will affect each other. However, in this case, because in an open distribution box can be in direct contact with the cable, thus reducing trace depth is not very important. Positioning cables In order to successfully position cable in this type of application, you must understand theoretically work on the principle. Illustrated by a covered outlet, for example. In this case, the lighting is often the only access to the cable of the socket. From the socket, transmitter signal was sent to the cable. Connection of the transmitter as described above voltage-free condition. Grounded outlet or extension cord near grounding is used to. Now, tracks the appropriate cables, until the signal cannot be received. Operator can manually adjust the sensitivity of the receiver, depending on installation in wall depth must be increased or decreased sensitivity of the receiver. Once the received signal, the receiver will display the letters ' f ', as well as the received signal strength. In addition, the signal can be set on the transmitter sends 3 different intensities. Track cables in such a way, until you reach the end, and navigate to the appropriate junction box or switch box. Well grounded transmitter output signal for voltage-free application is very important. On the cable is connected to the receive signal. Instances of locating cable faults If the transmitter is connected to one end of the cable to locating a breakpoint due to magnetic disturbances, sometimes only about to locate the location of the breakpoint. In this case, another sent a different signal code is very helpful. For shielded cables, such as aerial cables, signal will be displayed on the screen. Know in advance also will help the process of building structures. Hard concrete of steel also has a negative impact on tracking signal. Grounding shield of reinforced concrete is likely to play a role, will not receive the signal. Recommendations prior to the initial operation, the first known system for the actual test. This is best way to users familiar with the instrument. Using special cable cable detector positioning in field testing has many advantages. Using trial and error (Trial-and-Error) in cable, such as punch through walls, can damage the building structure and can damage the cable itself. New Fluke-2042Cable detector is to provide help in the everyday life.

Position cable break

With additional transmitter locate cable break Locating failures in electric floor heating A very interesting application is to locate fault in the electric floor heating. For example, when laying out warm when it is not working properly. A common cause of this failure is the laying of floor heating floor is accidentally cut or damaged. For heaters with a protective layer, and able to see transmit signal on the screen is very important.

Locating failures in electric floor heating Tracing underground cables and pipes Use Fluke-2042Cable detector can also keep track of buried cables. When dealing with external lighting systems, this feature is very useful. The maximum depth of this type of application is 2.5M.