Product parameters:
Features:
• Frequency range: 0.15~1050MHz
• 4-digit digital display (center frequency, 0.1MHz resolution)
• -100~+13dBm range, 20KHz, 400KHz If bandwidth and 4KHz video filters
• Tracking generator
·Output amplitude: +0~-50dBm (50 ω)
Uses:
An Taixin Spectrum Analyzer information that normally appears not the processed signal, voltage, power, cycle, waveforms, sideband and frequency of wave distortion, dual-tone intermodulation distortion and clutter
Detection. Good remote control, intercom, measuring transmitter receiver, cordless phone survey for analysis. Also can be widely used in teaching and research. An Taixin spectrum analyzers can really
See electrical signals (such as radio frequency pulse signal) images using Fourier series expansion, more easy to understand teaching, scientific research better.
Cable TV CATV and telecommunications testing:
An Taixin spectrum analyzers meet the impedance converters (50 ω conversion 75 ω), cable television (CATV) and communications
Wired and wireless systems for inspection and analysis of signal frequency.
GSM, CDMA mobile phone repair:
An Taixin Spectrum Analyzer can detect mobile phone RF local oscillator signal if signal transmitter signal
Etc. AT5011+ series Spectrum Analyzer maintenance phone no network failure point, fast and accurate fault
Repair.
Frequency extension:
• Instrument combined with frequency Extender (AT5000-F1) can measure the frequency extension to 2000MHz (qualitative measure),
Can only be used to enter a channel extension, and cannot be used to expand the trace source measurement range 1050 MHz~2050
MHz.
• Instrument combined with frequency Extender (AT5000-F2) can measure the frequency extension to 3000MHz (qualitative measure),
Can only be used to enter a channel extension, cannot be used to expand the trace source for measuring 2050 MHz~3050
MHz.
Electromagnetic compatibility testing (EMC):
• Measuring all kinds of electronic devices with the launch of the features of harmful electromagnetic waves.
• Cooperate with EMI AT-166 EMI test for tested products.
• Combined with electric field Monopole probe AZ-530-E for testing radiated emissions testing.
• Combined with magnetic field probe AZ-530-M on the inner circuit of the product being tested sources of interference for testing.
• High-impedance probe AZ-530-H on the inner circuit of the product being tested for maintenance testing.
Listen signal function:
FM demodulation signal Spectrum Analyzer output, and analyse the content of unencrypted radio stations that can be used to know
Don't influence the noise of radio signals, timely analysis from the air station, in order to determine checked
Measuring equipment for normal operation and measurement of some unknown third party radio activity.
Frequency sweep function:
• Frequency: set the Center frequencies of the Spectrum Analyzer, and then when the sweep width to '0' Hz signal output
For frequency hopping signals.
• Sweep: instrument combined with tracking function signal source products to be measured pass band frequency sweep will be measured
Product series in the signal trace source (output) and instrument detection channel (input), and set the required frequency
Rate can be detected.
Technical specifications:
Frequency
Range: 0.15~1050MHz
Center frequency display accuracy: ± 2%x spectral width +5x10-3x frequency +100KHz
Marking accuracy: ± 0.1% band +100HKz
Frequency display resolution: 100KHz (4-digit LED)
Sweep width: 100KHz/case ~100MHz/case 125 gears and 0Hz/(0 scan), accuracy: ± 10%
Frequency stability: better than 150KHz/hours
Wide frequency band ( -3dB): 20KHz (± 50%); 400KHz+ (0,-40%), the video filter (pass);
4KHz
Scan rate: 43Hz
Range
Range: -100~+13dBm
Display range: 80dB (10dB/)
Reference level: -27dB at 500MHz
Average noise level: -90dBm (20KHz, dBm typical)
Distortion: 2 3 Harmonic ﹤ -55dBc
3-order intermodulation: -70dBc
Sensitivity: better than -90dBm
A logarithmic scale: ± 2dB (without the attenuator), 500MHz
Enter
Impedance: 50 ω
Connectors: n (f) connector
Attenuator: 0~40dB (step 4x10dB)
Input attenuator accuracy: ± 1dB/10dB
Maximum input level: +10dBm, 25VDC (0dB attenuation), +20dBm (40dB attenuator)
Tracking generator
Output frequency range: 0.15MHz~1050MHz
Output level ranges: -50~+1dBm (10dB step variable adjustment)
Output attenuator: 0~40dB (4x10dB)
Accuracy (attenuator): ± 1dB
Output impedance: 50 ω (BNC)
Frequency range: 0.15~1050MHz
Frequency Rate: ± 1.5dB
Frequency injection interference (RFI): ﹤ 20dB
General configuration
Power supply: 200VAC/110 VAC ± 10%,50Hz~60Hz
Track alignment: adjust the Panel (TR)
Power consumption: 20W ± 20%
Protection: security level 1 (IEC1010-1)
Size: 285 (w) x125 (h) x380 (d) mm
Weight: about 7 kg