Product parameters:
United Kingdom Sheen minimum film forming temperature meter MFFT-60 MFFT-90
Features:
10 temperature sensor 37mm spacing
Sensor accuracy 0.1 ℃
Temperature can be displayed on each point, or you can switch to differential mode, shown is the temperature difference between the left and right between two proximity sensors
483*235mm nickel plate, easy to maintain
Drying and cooling failure tips
Standard configuration:
Minimum film forming temperature Tester, air and water connector, 25 μg m*1Cubic coating , Circuit sensors, guide rod, indicating Crystal 5 dispensing device
Spatula, fuse and manuals.
Selection of instruments:
MFFT-60 minimum film forming temperature:-5 ℃ ~ + 60℃ 6
MFFT-90 minimum film forming temperature:-5 c ~+90 c 9
Details:
In SHEEN MFFT Minimum film forming temperature measurement, cooling and heating elements are grouped together with nickel-plated copper plate, with particular attention to ensure that it is in excellent
Good thermal coupling. This leads to its own power, and can respond quickly to reach the operating balance. Excellent insulation ensures simple operation conditions and
Stable.
ASTM D 2354/86Required tests on the surface, there is a constant flow of clean, dry air. Tests show that the uniform airflow is determined by device
Enclosure air conditioning units (including pressure regulators, filters, drying and flow controllers) to deliver it. Tube to a clean, dry
Air flow to a sophisticated distribution system design of porous sintered bronze, it will be uniformly distributed in the air on the surface of the test. If you are using MFFT To test applied to the
On the surface of the sample is consistent with the results of multiple LaTeX article, it indicates that the air final arrangements were perfect right.
Equipped with hinged metal frames and transparent plastic cover, including the test plates, can also play a role in insulation.
Vintage MFFT , At the entrance to the air will have a snowflake, SHEEN Products designed to solve this problem. However, if you keep the air dry
Dry disconnect circuit, or let the lid open, snowflake on test plates, you will easy to see Frost and cold lines.
In SHEENFFT In Vietnam 37mm Interval, the measuring accuracy of 0.1Each point on the displayed temperature can be, or can be used to cut
Change to differential mode, shows will be the points from their left and right between two proximity sensors of temperature, should be the same. We provide one can receive
Since moving the probe in the jack plug. The probe is used for testing the temperature at one point on the Board, or to test MFFT Procedures for calibrating and temperature control