Product parameters:
The testo 320 Flue Gas Analysis Suite will be a very reliable tool for heating system engineers performing heating system measurement tasks such as identifying faults and emergencies, monitoring statutory limits, and routine maintenance of heating systems. Flue gas analyzer package, including many very useful accessories, can be used to measure flue gas composition and concentration, pumping force, pressure, environmental CO, environmental CO 2, Temperature and gas leakage and so on.
The testo 320 flue gas analysis suite also has a high-resolution color display that makes it easier for users to view data even in low light conditions. 500 measurement protocols can be stored.
Trusted quality: testo 320 flue gas analyzer, tested in accordance with EN 50379, Part 1-3 and 1st German Federal Immission Control Ordinance (BImSchV), Part 1-2 2Compensation) sensor, also in line with Part3). You will have a one year warranty after purchasing the testo 320 flue gas analyzer (main unit, sampling probe, O 2 / CO sensor).
- testo 320 flue gas analyzer, including O 2Sensors and CO (H 2Compensation) sensor, rechargeable lithium battery (0632 3220)
- Compact flue gas sampling probe: 300 mm long, Ø 6 mm (0600 9741)
- USB charging adapter with connecting cable (0554 1105)
- Instrument case (0516 3300)
CO (H compensation)
Measuring range | 0 to 8000 ppm |
measurement accuracy | ± 10 ppm or ± 10% of the measured value (0 to 200 ppm) ± 20 ppm or ± 5% of the measured value (201 to 2000 ppm) ± 10% of the measured value (2001 ~ 8000 ppm) |
Resolution | 1 ppm |
Corresponding time | <40 s |
CO low (H ?? compensation)
Measuring range | 0 to 500 ppm |
measurement accuracy | ± 2 ppm (0 to 39 ppm) ± 5% of the measured value (40 ~ 500 ppm) |
Resolution | 1.0 ppm |
Corresponding time | <40 s |
Force measurement
Measuring range | -9.99 to +40 hPa |
measurement accuracy | ± 0.02 hPa or ± 5 hPa (-0.50 to +0.60 hPa) 0.03 to +1 hPa ± 1.5% of the measured value (+3.01 ~ +40.00 hPa) |
Resolution | 0.01 hPa Use the Precision Force option 0.001 hPa |
temperature
Measuring range | -40 to +1200 ° C |
measurement accuracy | ± 0.5 ° C (0 to +100.0 ° C) ± 0.5% of the measured value (the remaining range) |
Resolution | 0.1 ° C (-40 to +999.9 ° C) 1 ° C (> +1000 ° C) |
Determination of effectiveness
Measuring range | 0 ~ 120 % |
Resolution | 0.1 % |
Flue gas loss
Measuring range | 0 ~ 99.9 % |
Resolution | 0.1 % |
CO measurement (calculated by O ??)
Measuring range | 0 ~ CO max (display range) |
measurement accuracy | ± 0.2 Vol.% |
Resolution | 0.1 Vol.% |
Wind speed
Pressure measurement
Measuring range | 0 to +300 hPa |
measurement accuracy | ± 0.5 hPa (0.0 to 50.0 hPa) ± 1% of the measured value (50.1 ~ 100.0 hPa) ± 1.5% of the measured value (the remaining range) |
Resolution | 0.1 hPa Use precision pressure option 0.01 hPa |
CO measurement (without H compensation)
Measuring range | 0 to 4000 ppm |
measurement accuracy | ± 20 ppm (0 to 400 ppm) ± 5% of the measured value (401 to 2000 ppm) ± 10% of the measured value (2001 ~ 4000 ppm) |
Resolution | 1 ppm |
CO environmental measurement
Measuring range | 0 to 500 ppm |
measurement accuracy | ± 5 ppm (0 to 100 ppm) ± 5% of measured value (> 100 ppm) |
Resolution | 1 ppm |
Use the CO probe 0632 3331
Environmental measurement
Measuring range | 0 to 1 Vol.% 0 to 10,000 ppm |
measurement accuracy | ± 75 ppm or ± 3% of measured value (0 to 5000 ppm) ± 150 ppm or ± 5% of the measured value (5001 to 10,000 ppm) |
Flammable gas leakage
Measuring range | 0 ~ 10000 ppm CH ?? / C ?? H ??; Display range |
measurement accuracy | Alarm signal optical display (LED); buzzer sound alarm |
Corresponding time | <2 s |
Use a gas leak detector
Precision pressure probe with temperature compensation
Technical Parameters
Storage temperature | -20 to +50 ° C |
weight | 573 g |
diameter | 240 x 85 x 65 mm |
Operating temperature | -5 to +45 ° C |
Warranty | 1 year |
Display size | 240 x 320 pixels |
Display characteristics | Color graphics display |
power supply | Rechargeable battery: 3.7 V / 2400 mAh; Power supply: 6 V / 1.2 A |
Maximum memory | 500 readings |