Product parameters:
Infrared thermometer temperature measurement is based on the theory of Planck's radiation law, according to ,By measuring infrared radiation to be measured energy ,Blackbody calibration ,To determine the target temperature. Infrared thermometer non-contact measurement, response speed, without disturbing the target temperature distribution characteristics. Cannot be measured with a contact of target, target ,Measurement of target temperature and temperature changes rapidly ,Infrared thermometer has its unique effect. For the development of modern measurement technology offers a new means of measurement. Compared with the traditional temperature measurement devices, infrared thermometer with comfort, accuracy and safety advantages.
Product description
DT-8856H Is a professional handheld non-contact infrared thermometer, using simple, solid design, high accuracy and temperature range as well as wide. It has a laser sight, with backlight display ,Maximum, minimum, average, poor value, data retention, high and low temperature alarms, adjustable emissivity, and automatic power off function.
The handheld non-contact infrared thermometer for measuring those traditional contact measurement method is not suitable to measure the surface temperature of an object (such as moving, electrically charged surfaces and hard to reach objects).
Can be used in heating, ventilation, electric power, transportation, chemical, metallurgical and other fields.
Product features
1. Non-contact accurate temperature measurement
2. High ratio of optical measuring distances to objects (D: S=16: 1)
3. Wide range of temperature measurement range: -50~ 1350oC (-58~ -2462℉)
4. Unique new chassis design
5. Built-in laser sight
6. Automatically maintained
7. oC/oF Convert button
8. Emissivity adjustment 0.10To1.0
9. MAX,MIN,DIF, AVG Temperature display
10. With backlight LCD Display
11. Resolution: less than 2000º 0.1oC/oF , Is greater than 2000º 1oC/oF
12. High and low temperature alarm set
Switch settings:
C/F Translation: oCAnd ºFButton to select the temperature (ºC/ºF)
Open /Turn off the lock (LOCK ): To lock the instrument to keep measuring, place the Middle knob LOCK ON/OFF Slide to the right ON.
Alarm setting (SET ALARM ): Open the alarm you want to set, place the following button SET ALARM Slide to the right ON.
To set the high alarm value, the low alarm value and the emissivity value, first by pushing the trigger or press MODE Keys to activate the display, and then press MODE Key until the appropriate code appears in the lower left corner of the display, press the up and down keys to adjust to the desired value.
Measuring temperature with accuracy
Ensure the accuracy of operation ambient temperature: 23 to 25ºC (73 to 77ºF)
-50oC ~ -20oC (-58oF to 68oF)±5oC/+9oF
-20oC ~ 200oC (68oF to 392oF)±1.5% of reading ±2.0ºC/±3.6oF
201oC ~ 538oC (393oF to 1000.4oF)±2.0% of reading ±2ºC(±3.6ºF)
539oC ~ 1000oC (1000.4oF to 1832 oF)
±3.0% of reading ±5ºC(±9ºF)
Technical product specification
Resolution :Is less than 2000º 0.1ºC/ºF, Is greater than 2000º 1ºC/ºF
Precision:
Environment operating temperature: 18 ~ 28oC (64 ~ 82℉)Measurement accuracy is as follows:
-50 ~ -20℃(-58~ -4℉):±5oC(±9℉)
-20 ~ 200℃(-4 ~ 392℉):±1.5%Readings +2℃(±3.6℉);
200~ 538℃(392 ~ 1000℉):±2.0%Readings +2℃(±3.6℉);
538 ~ 1350℃(1000 ~ 2372℉):±3.0%Reading ±5℃(±9℉)
1350 ~ 1550℃(2372 ~ 2912℉):±3.5%Reading ±5℃(±9℉)
Response time :Is less than 1Second
Spectral response :8~14um
Emissivity :Digital adjustments 0.10To1.0
Out of range hints :LCD Displays '-0L' ,' 0L'
Polar display :Automatic (Nothing displayed on the positive);
(-)Show negative
Diode laser Output ﹤1mW,Wavelength 630~670nm,Class 2(II)Class
Operating temperature :0 ~ 50℃(32~ 122℉)
Storage temperature range :–20~ 60℃(-4 ~ 140℉)
Relative humidity :10%~90%RH (Action) , ﹤80%RH (Storage)
Power supply 9VBattery , NEDA 1604A Or IEC 6LR61,Or others with the specifications of the battery
Weight 290g (10.2 oz.)
Dimensions 100 x 56 x 230mm (3.9 x 2.2 x 9.0' )
Safety design standards In line with the European CE Safety specifications
Standard packaging: instruction manual, warranty card, tripod, 9VBattery ,Box and color box.