| Basic parameters |
| Resistance range | 3.100m/31.00m/310.0m/3.100Ω |
| Precision | ±0.8%rdg. ±6dgt.; 3.000m Dan Liangcheng: ± 1.0%RDG. ±8dgt. |
| Voltage ranges | ±6.000V/60.00V |
| Precision | ±0.08%rdg. ±6 dgt |
| Temperature measurement range | -10.0 ° C~ 60.0 ° c (9460) |
| Precision | ±1°C |
| Testing frequency | 1kHz±30Hz |
| Test current (range) | 150mA (3m/30mΩ) , 15mA (300mΩ) , 1.5mA (3Ω) ; Open circuit Terminal voltage up to 5V |
| The maximum permissible voltage | 60V DC (no AC) |
| Comparator | 1TH and 2nd resistance thresholds, minimum voltage threshold |
| Number of buffers can be set more | 200 |
| Data storage | 4800 Group (date and time, resistance, voltage, temperature, compare value, result) |
| PC interface | USB (included with available software and PC communication) |
| Power supply | Section 8 AA alkaline batteries can be used continuously for about 10 hours |
| Dimensions and weights | 192W×121H×55D mm, 790g |
| Annex | 9465-10-pin test cable X1, USB cable X1, application software CDx1, carrying case X1 strap X1, LR6 alkaline battery x8 replacement fuse X1, zero X1 |