1.ATP detection of microbial total residues of food + ATP
2.ATP detection immediately notify links cleaning results
3. the trend according to ATP testing data controlled cleaning hygiene
3M ™ Clean-Trace ™ ATP fluorescence detectors are widely used in food, public health, cosmetics, water treatment, health care and other fields. Customers through the use of this instrument and supporting test can effectively monitor pollution due to microorganisms, to take prompt and effective response measures, reduce risk, and preventive measures.
Germicidal efficacy of traditional detection methods, generally used for sampling after sterilization and vaccination to the culture plate for 24-hour culture, by comparing the observed before and after sterilization on growth of bacteria in order to determine the effects of sterilization.
This method is correct, but the biggest disadvantage of time consuming too much, 48 hours after results cannot immediate adjustments to the sterilization process, which could cause sterilization are not up to the desired state.
ATP germicidal efficacy of rapid testing methods are based on the ATP (adenosine triphosphate) three detection principle of phosphonic acid acyl glycosides ... ATP is a in all plants, bacteria, fungi, yeast, bacteria and other living cells contain a unit of energy. All living organisms contain ATP. Detection of ATP to reflect all the much of microorganism. Microbial ATP in a sample after it has been extracted, and luciferase (Luciferase) and luciferin (Luciferin) under the action of fluorescence,, is proportional to the amount of light and ATP. the amount of light can be detected by Biotrace fluorometer, live microorganisms more ATP, the more, the greater the amount of light. In order to detect microorganisms in a sample.
3M ATP Fluorescence detection Analyzer technical parameters:
1. Instrument Lightweight, weighs only 400Gram To facilitate site operation
2. **Detector Pmt PMT using a photodiode with a small, sensitive, rapid advantages, suitable for low light
Signal detection and receives, makes it possible to achieve the true sensitivity is higher.
3. **Detection range Wai : 0-999999RLU
4. Detection Sensitivity up 10-15mol ATP
5. ** Can be stored 10000A check Measuring results
6. Can be stored 100Generic classifier Sampling plans sampling plans may be established 300Generic classifier Sampling points
7. Can be stored 2000A meter Sampling points
8. ** A variety of Language-selection user interface, including the selection of Chinese multilingual user interface, you can choose according to the actual needs of customers at a faster, more
Skilled use of the apparatus through the testing process, as well as data analysis.
9. ** Instrument The repeatability of the test, CV%Value (The coefficient of variation) is equal to 7.4% (See annex)
10.Instrument Reading time 10Second
11. ** Detachable Discharge, can be repeatedly filled with lithium-ion batteries, power ensures continuous operation 36Hour
12.Instrument Display the electricity allowance and charging status
13. ** Features Auto inspection and alarm function
(1) post function guarantees when ATP power instrument Each element in the normal working condition;
(2) the alarm function to tell Customers, instruments with particular attention, in a non-functional State, in order to find the problem as soon as possible, and troubleshooting.
14. 240x160 Like Effect of liquid crystal display screen with backlight function, the user can customize the backlight duration
15.Detection Cavity /Cover Dynamic sampling rod into the instrument and alarm function should be tested, if not get out in time, because a busy work could
Forget residue sampling Rod (especially each detection of last a root), so in detection Hou of shelved Shi, if flat put instrument, smear rod in of solution on has may outside leak to cavity body, caused pollution, light who caused instrument background value increased, heavy who effect optical components of detection results, that machine fault, so this alarm function can warning operation who in detection end Hou took out smear rod, while also habit good of operation habits.
16.Can be Edit the download detection scheme to their own instrument and according to plan testing
17.Plan Qualified limits may be established within the model, the instrument automatically result qualified and unqualified and have Retest Function Again after cleaning inspection in the inspection plan data directly in this section.
18.Support Trend analysis software can provide 9Kinds of knots If filter mode, 5Species Reporting mode and 10Types of charts Mode, automatic data import Excel Table
19.Since Define user permissions feature
20.According to Enterprise at different sites recommend different limits (See annex Table)
Report mining Sample bar parameters:
21. 3M Clean - Trace Ying Optical sampling rods contain sufficient and stable liquid fluorescein /Fluorescence An enzyme, and overcome the shortcomings of lyophilized enzyme reactions are not balanced; And does not require additional reaction tube
22.Sample Rod 10A month (Refrigerated) within the retention period, to maintain 95%To On the enzyme activity