TMJ9701 testing machine | Standard-type salt spray test machine

TMJ9701 testing machine | Standard-type salt spray test machine

1+
12500 CNY (1820.04USD)
3+
12300 CNY (1790.92USD)
5+
12200 CNY (1776.36USD)

add to cart

Product parameters:

  • Customized processing: no
  • Brand: meet macros
  • Model: TMJ9701


Salt spray test machine standard A12-TMJ9701

Test space: 900x600x500 (LxDxH) m/m

Used materials:

1. laboratories: mining 6m/m P.V.C, PVC thickness, temperature resistance up to 80 ℃

2. laboratory seal cover: transparent acrylic impact resistance, thickness 6 m/m more

3. laboratory filling: recovery of hidden water gauge, easy for cleaning difficult to break down

4. saturate air barrel: mining and SUS#304 stainless steel Autoclavable plastic bucket, insulation is the best

5. laboratory basket: graphic type, adjustable angle of 15 ° c and 30 ° c angle, surrounded by falling mist and fog in identical tests placed more

Use: according to the CNS,JIS,ASTM specifications, set the thermostat control

1. the salt spray test: NSS, ACSS (1) laboratory: 35 ° c ± 1 ℃ (2) saturated air tank: 47 ± 1 ℃

2. corrosion resistance test: CASS (1) laboratory: 50 ℃ ± 1 (2) saturated air tank: 63 ± 1 ℃

Spray method:

1. principle of Bai Knut draw salt water and spray, uniform atomization, no blocking crystallization phenomenon to ensure continuous testing standard

2. nozzle: made of special glass, you can adjust the amount of mist and spray angle

3. spray volume:/1hr 0.5-3.5ml,80C ㎡ (16hr average)

Mist method: pneumatic mist, fog ruled out of using air pressure to make room, so quality is not affected by salt spray effect

Heating system: mining water heating methods, according to the CNS,JIS,ASTM specifications, automatically when temperature reaches ON,OFF switch

Control system:

1. test room temperature controller 0~ 99.9 degrees f (liquid crystal digital display) with PID automatic calculation control error is ± 0.3 c

2. saturate air barrel temperature controller 0~ 99.9 degrees f (liquid crystal digital display) with PID automatic calculation control error is ± 0.3 c

3. the heating tank for liquid expansion temperature control for safety 0~ 120 ℃

4. the saturated air barrels of liquid expansion temperature control 0~ security 120 ℃

5. liquid crystal automatic: 9.9S-9990HR ANLY AH5R (time to beep 10 seconds automatically, and cut off the spray heating system)

6. when the product: 0-9999.9 HR

7. level of precision adjustment of pressure: air filter

8. pressure gauge: 2.5 Kg/c square IK-2.5

9. the illumination Board withhold switch: can continue to withhold more than 20,000 times

10. only pressure display 1.00kg/cm0.01kg/cm

11. compliance with specifications such as ASTM,ISO,CNS,JIS,BS the only fault and error detection indicates, contains low level detection, compressor overload, over-temperature warning, timers, low-salt liquid warning (9701) stereo ring with reinforcement structure permanent deformation

Brand: business