Product parameters:
Output
CH1 / CH2
CH3
GPC-1850D
0 to 18 V / 0 to 5A
5V / 3A Max
GPC-6030D
0 to 60 V / 0 to 3A
5V / 3A Max
GPC-3060D
0 to 30 V / 0 to 6A
5V / 3A Max
GPC-3030DN
0 to 30 V / 0 to 3A
5V / 3A Max
Operating mode
alone
Two groups are adjustable with one set 5V Fixed output
Output by 0 To rated voltage and 0 To the rated current
In series
At any rated current, the output from 0 To + Rated voltage
At rated current, the output from 0 To twice the rated voltage
in parallel
At rated voltage, the output from 0 To twice the rated current
5V Fixed output
Regulation rate
Power regulation rate < 5mV
Load regulation rate < 10mV
Ripple and noise
< 2mVrms
Voltage accuracy
5V + 0.25V
Output current
3A
Synchronous tracking operation?
Tracking error
< 0.5% + 10 mV Master Display
Series adjustment rate
< 300mV
Constant voltage operation
Regulation rate
Power regulation rate < 0.01% + 3 mV
Load regulation rate < 0.01% + 3 mV (Rated current < 3A)
< 0.02% + 5 mV (Rated current < 10A)
Ripple and noise
< 1 mVrms 5 Hz to 1 MHz
Response Time
< 100 [mu] S (50% Load fluctuation , Minimum load 0.5A)
Constant current operation
Regulation rate
Power regulation rate < 0.2% + 3 mA
Load regulation rate < 0.2% + 3 mA
Ripple current
< 3mArms
Header
Digital
3 Bits 0.5 'LED display
Accuracy + (0.5% Read value + 2 Bits)
insulation
Chassis to terminal
20MΩ or above (DC 500V)
Chassis to the power cord
30MΩ or above (DC 500V)
using electric
communicate with 100V / 120V / 220V / 240V +10%, 50/60 Hz
annex
power cable x 1,
Operation Manual x 1,
Test line GTL-105 x 3 (<3A) or GTL-104 x 3 (<10A)
size
255(width ) x 145(high ) x 335(long ) Mm