Product parameters:
One High precision battery monitor system application: lithium polymer, lithium-ion, nickel metal hydride, nickel cadmium, lead-acid battery performance testing; Battery materials research; Small batch sorting battery production and capacity; Integrated battery, laptop battery test.
Two Stable and reliable system, each channel has a separate constant current constant voltage source and the hardware constant power discharge and constant resistance discharge.
Third, the running of each channel can be set independently; Increasing set of professional programmes; Under any of the ' stop ' (including power) work step ' continue ' feature. Through bad nesting.
Four, data acquisition speed, accurately capture details of change of voltage and current, have the log function. Powerful curves and data processing, and reporting capabilities. Curves and data can be exported to Excel, Word, data and curves can be edited.
Five fixture range, can adapt to different types of batteries, button cell, battery pack testing.
Six model range: you can design and manufacture according to customer demand current 1mA~1000A voltage 2V~500V range of various types of equipment, increase the negative voltage.
Seven, available offline, (Measurable temperature and resistance ), And SMbus features of laptop batteries. (In this case with internal resistance and temperature model)
Eight, handed out by the precision of voltage and current calibration software, can change unit number, variable drive.
Nine optional serial ports, USB and network connections. C/s mode, you can remotely monitor.
| 5V3000mA battery testing device | |||||||||||||||
| Device model: | 5 | V | 3000 | mA | Battery testing equipment | - | - | A1 | |||||||
| Indicators project | Indicator parameters | ||||||||||||||
| Input power | AC 220V ±10% / 50Hz | ||||||||||||||
| Max input power | 224000 | mW | |||||||||||||
| Resolution | AD: 16bit; DA: 12bit | ||||||||||||||
| Input impedance | ≥1MΩ | ||||||||||||||
| Voltage | Measuring range per channel | Charge: 10mV~5V | Discharge: 10mV~5V | ||||||||||||
| Minimum discharge voltage | 0.8V | ||||||||||||||
| Precision | ± 0.1% of FS | ||||||||||||||
| Stability | ± 0.1% of FS | ||||||||||||||
| Current electricity | Each channel and output range | Charging: discharge 6mA~3000mA: 6mA~3000mA | |||||||||||||
| Precision | ± 0.1% of FS | ||||||||||||||
| Stability | ± 0.1% of FS | ||||||||||||||
| Power | Single channel output power | 15000mW | |||||||||||||
| Stability | ± 0.2% of FS | ||||||||||||||
| Time | Current response time | Current 3000mA hardware response time of 20ms | |||||||||||||
| Step time frame | ≤ (365*24) hours/step | Time formats supported 00:00:00 (h, min, s) | |||||||||||||
| Data records | Data recording | Δ t time range: (1s~60000s) | |||||||||||||
| Voltage δ u: (10mV~5V) | |||||||||||||||
| Current Delta-I: (6mA~3000mA) | |||||||||||||||
| Recording frequency | 1Hz | ||||||||||||||
| Charging | Charge mode | Constant current, constant voltage, constant current and constant voltage charging | |||||||||||||
| Closing conditions | Voltage, current, relative time, volume | ||||||||||||||
| Discharge | Discharge mode | Constant-current discharge, constant power discharge | |||||||||||||
| Closing conditions | Voltage, current, relative time, volume | ||||||||||||||
| Cycle | Test ranges | 1~65535 times | |||||||||||||
| Single-cycle steps | 63 | ||||||||||||||
| Nesting cycle | With nested loops function, supports up to 3 levels of nesting | ||||||||||||||
| Protect | Security protection | Power loss data protection | |||||||||||||
| NULL | |||||||||||||||
| Set the security conditions, set the parameters include: maximum voltage, minimum voltage and current limit, current limit delay time | |||||||||||||||
| Channel characteristics | Constant-current source with constant voltage source independent double closed-loop structure | ||||||||||||||
| Channel control mode | Independent control | ||||||||||||||
| Voltage and current sampling | Four-wire connection | ||||||||||||||
| Noise | ﹤85dB | ||||||||||||||
| Database | Do not fill (delete this) | ||||||||||||||
| PC communication | RS232 / RS485 | ||||||||||||||
| The data output mode | EXCEL, TXT, chart | ||||||||||||||
| Communication interface | Serial port | ||||||||||||||
| Each channel | 8 | ||||||||||||||
| Equipment working environment requirements | |||||||||||||||
| Indicators project | Indicator parameters | ||||||||||||||
| Operating temperature range | 0 ℃ ~ 40℃ | ||||||||||||||
| Storage temperature range | -10 ℃ ~ 50℃ | ||||||||||||||
| Operating relative humidity range | 70% RH or less (no condensation) | ||||||||||||||
| Storage relative humidity range | 80% RH or less (no condensation) | ||||||||||||||