Germany imported HDT 3500 fault detector | Continuity-continuity Tester continuity Tester

Germany imported HDT 3500 fault detector | Continuity-continuity Tester continuity Tester

960 CNY (139.78USD)

add to cart

Product parameters:

  • Brand: HDT
  • Model: 3500
  • Type: Digital Multimeters
  • Style: handheld multimeter
  • Usage: professional use


Germany HDT/continuity detector and off detector
Product number: 3500
Products used in circuit boards, equipment, lines, through fault detection of electric power, and have the line function.
Instruments also has a lighting function, can be used in environments with poor visibility.
Can be measured: 0-2 w/2 w-15 w/15 ω -10K ω/off
Because of the test current of 200mA (safety requirements), grounding resistance measurement is available for general electrical equipment, such as measuring results is less than 2 ω, then qualified. (Only as a reference measurement, not as a substitute for safety testing instruments)
Real shot pictures
Positive
Panel
Behind
Annex
Functions and features:
• Determine whether wire or line resistance conduction
• Have different test results for sound and light show
• Lighting function
• Resistance to judge range from less than 2 ω 2 ω-15 ω 15 ω ~ 10 k ω
• Testing current of 10mA and 200 mA selectable
◇ Randomly attached to the test line and 2 test probe, and one Alligator Clip, Sino-German and English user manual
• 1 9V battery
• Shock resistant structure, solid and shock-proof ABS enclosure, plus eco-friendly rubber boot.
Measuring mode:
Remember: the conductor or circuit to be measured is not live!!! If charged, please do not discharge lamps the eyes!!!
Instruments and toggle switch at the top, optional 10mA or 200mA
Switch position in ' ﹤ 10mA'
① When the measured resistance is 0-15 ω appears beeps, the Green LED lights up.
When the measured resistance is between 15 ω -10K ω, only the Green LED is lit.
Switch position in '200mA'
① When the measured resistance is less than 2 ω, lights flashing and beeping. Mainly used for measuring Earth resistance.
II if the resistance being measured between 2 ω ~ 15 ω, only beeps.
Measured lines or if the measured resistance is greater than 15 ω (﹤ 10K), the Green LED lights.
④ If the circuit to be measured, or measured resistance is greater than 10K, then nothing happens.
The battery self-test:
Check that the battery voltage is sufficient, or must be replaced, instrument selection switch at the top of ' ﹤ 10mA', two test lead probe to touch each other. If the battery is good, you will hear a sound signal and the Green LED lights. If you only hear the sound signals, and the Green LED lights are not on, then the battery needs to be replaced.
Torch lighting functions:
Because the instrument has a high brightness lighting, do not set the eyes look straight into the light source!
The instrument is configured on the torch lighting function, when the switch is turned to ', ' sustainable lighting.
Technical parameters:
Switch position in ' ﹤ 10mA'
Test current is less than 10mA
0-15 ω: green LED lights, beeps
15 ω -10K ω: green LED light only
Switch position in '200mA'
Maximum test current of 200mA (resistance ≤ 4 ω)
0-2 ω: lights flashing and beeping
2 ω-15 ω: green LED lights, beeps
15 ω -10K ω: only green LED lights
Voltage protection
230V AC/DC
External voltage (Red LEDs)
5V AC/13V DC
Safety standards
IEC/EN 61010-1, IEC/EN 61010-031
Power supply
9V battery IEC 6LR61
Dimensions
About 130 x 72 x 30 mm
Weight
About 250g
Standard configuration:
1 3500 fault detector
1 set test probes (including 2 probes + 1 Alligator Clip, color random)
1 9V battery
1 Chinese German English user manual