Product parameters:
- Brand: FLUKE/fluke
- Model: Fluke116C
- Customized processing: no
- AC current: 000
- DC voltage: 000
- AC voltage: 000
Fluke 116C digital multimeters to measure current function, designed specifically for the HVAC professional. It has HVAC instruments required for a variety of digital multimeter in measuring the current functions, including for the HVAC equipment and flame sensor temperature and microamp measurements for rapid troubleshooting.
Another Fluke 114 electrical multimeter, Fluke 115C multimeter with non-contact voltage measurement function electrical technicians by Fluke 117C multimeter.
- Built-in thermometer for HVAC applications
- UA for testing flame sensor measurements
- LoZ features: low input impedance to prevent errors due to false voltage readings
- White LED backlighting in a weak position can also be a powerful light reading
- Multimeter to measure current resistance, continuity, frequency and capacitance measurement
- Minimum/maximum/average measurements, recording signal fluctuations
- Compact ergonomic design for one-handed operation
- You can use magnetic meter hanging lace matching (ToolPak ™) without hand-holding can measure
- Safety grade CAT III 600 v
| Technical specifications |
| The maximum voltage between any Terminal and ground | |
| Surge protection | | 6 kV peak, according to IEC 61010-1 CAT III 600 v; Contamination level 2 |
|
| Display | | Numbers: | 6000 words, update 4/sec |
|
| Bar chart | | Paragraph 33, updated 32/sec |
|
| Working temperature | |
| Storage temperature | |
| Battery type | | 9 v alkaline battery, NEDA 1604A/IEC 6LR61 |
|
| Battery life | | 400 hours (typical value), no backlighting |
|
| Accuracy specifications |
| Multimeter to measure current DC mV | | Range: | 600.0 mV | | Resolution: | 0.1 mV | | Accuracy: | ± ((% Reading) + (Word)): 2% + 3 |
|
| Multimeter to measure current DC v | | Range/resolution: | 6.000 V / 0.001 V | | Range/resolution: | 60.00 V / 0.01 V | | Range/resolution: | 600.00 V / 0.1 V |
|
| Automatic voltage selection | | Range | 600.0 V | | Resolution: | 0.1 V | | Accuracy: | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (from 500 Hz to 1 kHz) |
|
| Multimeter to measure current MV Exchange 1True RMS | | Range: | 600.0 mV | | Resolution: | 0.1 mV | | Accuracy: | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (from 500 Hz to 1 kHz) |
|
| Multimeters measure AC voltage at the current 1True RMS | | Range/resolution: | 6.000 V / 0.001 V | | Range/resolution: | 60.00 V / 0.01 V | | Range/resolution: | 600.0 V / 0.1 V | | Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (from 500 Hz to 1 kHz) |
|
| Continuity | | Range | 600 ? | | Resolution: | 1 ? | | Accuracy: | Voice alarm ﹤ 20? When connected, ﹥ 250? Close; From 500 µ s or long-open circuit or short circuit. |
|
| Resistance | | Range/resolution: | 600.0 ? / 0.1 ? | | Range/resolution: | 6.000 k? / 0.001 k? | | Range/resolution: | 60.00 k? / 0.01 k? | | Range/resolution: | 600.0 k? / 0.1 k? | | Range/resolution: | 6.000 M? / 0.001 M? | | Accuracy: | 0.9 % + 1 | | Range/resolution: | 40.00 M? / 0.01 M? | | Accuracy: | 1.5 % + 2 |
|
| Diode test | | Range/resolution: | 2.000 V / 0.001 V | | Accuracy: | 0.9% + 2 |
|
| Capacitor | | Range/resolution: | 1000 nF / 1 nF | | Range/resolution: | 10.00 μF / 0.01 μF | | Range/resolution: | 100.0 μF / 0.1 μF | | Range/resolution: | 9999 μF / 1 μF | | Range/resolution: | 100 μ f to 1000 μg f | | Accuracy: | 1.9% + 2 | | Range/resolution: | ﹥ 1000 μF | | Accuracy: | 5% + 20% |
|
| Low input impedance | | Range: | 1 nF to 500 μg f | | Accuracy: | 10% + 2 (typical) |
|
| Temperature 2 (K-type thermocouple) | | Range/resolution: | '-40 ° c to 400 ° C/0.1 ° c | | Accuracy: | 1% + 102 | | Range/resolution: | '-40 ° f to 752 ° C/0.2 ° f | | Accuracy: | 1% + 182 |
|
| AC Mu a true RMS multimeter to measure current (45 Hz to 500 Hz) | | Range/resolution: | 600.0 μA / 0.1 μA | | Accuracy: | 1.0% + 2 |
|
| Multimeter to measure current μA | | Range/resolution: | 600.0 μA / 0.1 μA | | Accuracy: | 1.0% + 2 |
|
| Frequency (voltage or current inputs) 2 | | Range/resolution: | 99.99 Hz / 0.01 Hz | | Range/resolution: | 999.99 Hz / 0.1 Hz | | Range/resolution: | 9.999 Hz / 0.001 Hz | | Range/resolution: | 50.00 Hz / 0.01 Hz | | Accuracy: | 0.1% + 2 |
|
Note: 1) in addition to automatic low impedance (Auto-V LoZ) measurements, ranges are provided for all communication within the range 1 to 100%. Automatic low impedance (Auto-V LoZ) defined as 0V. Since not provided below input voltage range 1%, so when the disconnect test leads from the circuit, or the two test leads together and when a short circuit occurs, the instrument or other true RMS meter displays non-zero readings are normal. For voltage measurement, when 4,000 bits, crest factor ≤ 3; When the full degree, 1.5 per cent under peak coefficient of linear. AC voltage is AC coupled. LoZ and automatic voltage AC mV DC coupled. 2) temperature error (accuracy) does not contain the error of thermocouple probes. 3) frequency is AC-coupled, AC voltage, frequency from 45 Hz to 50 kHz.
| Mechanical and general technical specifications |
| Dimensions | |
| Weight | |
| The warranty period | |
| Model name | Description | Price List |
| Fluke 116 | HVAC multimeters/multimeter to measure current This model includes the following components: - 80BK integrated temperature probe
- Sheath
- 9 v battery, installed
- User manual
|
|