Product parameters:
Detection method: ISE method
Implementation of standards
"Concrete Test Code for Water Transport Engineering" JTJ 270-98
"Code for durability design of concrete structures"
"Technical specification for application of sea sand concrete" JGJ206-2010
"Hydraulic concrete test procedures" SL352-2006
Test method for homogeneity of concrete admixtures
"Ready - mix concrete" GB / T
Test indicators: chloride ion concentration, mass percentage
product description
In order to avoid premature corrosion of the steel, the chloride ion content in the concrete raw material is quite strict, and the relevant specification in our country specifically requires the concrete to be mixed with the sand, aggregate, cement, admixture, Concrete raw materials, it is necessary to test the content of chloride ions, from the fundamental to avoid excessive chloride ions into the concrete in the structure of chloride ion content of the test, for the assessment of structural safety play a significant role, The old structure of the transformation and repair provide a reference value.
The instrument follows the "concrete structure durability design specification" GB / T 50476-2008, "sea sand concrete application technical specification" JGJ206-2010, "water transport engineering concrete test procedure" JTJ 270-98 and other related standards manufacturing, the use of ion-selective electrode (Ion Selective Electrode, ISE method), through the provision of professional software and chemical anti-jamming reagents at room temperature rapid determination of concrete, sand, cement, mixed water and other inorganic materials, water-soluble chloride ion content, so as to achieve control of concrete The purpose of the early corrosion of the steel. The instrument light weight, compact body, easy to carry, suitable for on-site testing. Chloride ion concentration measurement range 10-5~ 10-1 M (mol • L-1) or 0.0001% to 30.00%.
Features
1. Can determine the concrete mixture, hard concrete, gravel, admixture, water and other materials, water-soluble chloride ion content, the direct output to the molar concentration and percentage of the unit results;
2. Built-in standard formula, the direct calculation of the concrete mixture of chloride ion content
3. Specific anti-ion interference agent, remove the cyanide, ammonia and other oxidation effects of manganese and lead and other metal ions complex effect
4. Exclusive linear regression coefficient calculation program, self-diagnostic instrument working status
5. Large-screen LCD direct display, real-time printing, a key to complete the test, the use of simple operation
6. Light weight, compact body, easy to carry users, suitable for on-site testing
7. Optional micro-printer, even if not through the computer can also be printed immediately
8. Original PC software, with the national computer software copyright
9. Large-capacity data storage, can store 100 test data, continuous data records, safe and reliable
Test objects: sea sand, ordinary sand, fresh concrete, hard concrete, cement, stones, admixtures, soil, concrete mixed water and other water-soluble chloride ions.
Detection principle
The rapid determination of chloride ion content of water, soluble substances such as concrete, gravel and admixture by ion selective electrode (ISE) ISE method was carried out. The chloride ion concentration measurement range 10-5~ 10-1 M (mol • L-1) mol / L or 0.0001% ~ 30.00%. The equipment is simple, can be used for on-site inspection, accurate and fast data, automatic data processing.
Technical Parameters
Operating voltage: DC 3.6V
measurement accuracy: < 10%
Data storage capacity:> 100
PC communication parameters: Baud rate 2400
Collection time: ≤ 3min
Standby time:> 24 hr
Weight: 0.4 kg
LCD Size: 128 * 128
Test procedure
1. Weigh the sample, add the appropriate amount of distilled water or extract
2. Calibrate the electrode and measure the solution to be measured
3. Print the measurement data
Test Results
1. Chloride ion concentration Cl (mol • L-1)
2. Chloride ion content (%)
3. Concrete chloride ion content (%)
Measurement range: 0.0001% ~ 30.00% (Cl ˉ), 10-5~ 10-1 M (mol • L-1)
Accuracy: ± 10% of reading (chloride ion)
Operating temperature: 0 ℃ ~ 40 ℃
Power supply: 1) 3.6V adapter; 2) lithium battery
Battery life: 12 months (8 hours per day)
Instrument specifications
Host size: 180 * 70 * 30 (mm)
Weight of main engine: 0.4 kg
Host Dimensions: 370 * 300 * 180 (mm)
Weight of main unit: 5 kg
System Configuration
1.NJCL-C rapid determination of chloride ion content
2. Domestic chloride ion selective electrode & calomel reference electrode
3. Calibration solution, anti-ion interference agent, chemical reagents
4. External micro printer (optional)
5. Charger
6. PC analysis software