Product parameters:
Range of application
Glass products, aerospace and other industries in situ measurements
Protective film, PC, acrylic plastic products such as light transmittance measurement
Other transparent or translucent material and light transmittance measurement
Note: this machine is not suitable for measuring print, matte, white material
Characteristics of the instrument
1. split-frame is equipped with a test stand, meet different testing needs of customers
2. high precision, fast, easy
3. Auto calibration and manual calibration
4.With two test modes: single mode and auto mode
5.Large storage capacity: can be recorded 999Set of measurement data
6.Three statistical function: maximum MAX Minimum MIN , The average MEA
7.Handles can be separated and host ,Convenient storage
8.Large size LCD Screen display, backlight and battery indicator
9.Free automatic shutdown for a long time, ensure the battery life
10.Equipped with high-grade aluminum case and EVA Lined for easy carrying
Technical parameters
1. light wavelength:
LH-210U:365nm for UV transmittance measurement
LH-210V : 380-760nm for visible light transmittance measurement
LH-210I:950nm for infrared transmittance measurement
2. Measuring range: 0-99.9%
3. Cent Based on syndrome differentiation Rate: 0.1%
4. Measurement accuracy: Is better than2%
5. Measurement of thickness Degrees : ≤50m
6. Measuring area : ≥10*10mm
7. Host: 170*87*55mm
8. handle Size: 34*71mm
9. Electricity Source: Two Section 3.7V lithium Battery
10.Use The environment : 0 ℃-40 ℃ Less than 85%
Equipment operation
1. Remove hosts from the rubber boot, open battery cover on 3.7V lithium battery
2. connect charger for one minute to activate product
3. Registration mark the bracket and insert the two handles or snap-keep the coaxial probe is not holding any object
4. Press the red key to boot, instrument calibration, the calibration complete screen displays 99.9%, if 0 represents alignment failed, you need to adjust the probe after reboot or press 'CAL' to manual calibration until the display 99.9%
5... Will be measured in the two handles, handle mark to maintain the same axis, press green button once and display the transmittance in the middle of the screen, while the bottom of the screen shows NO:001, data is recorded.
6... Instruments can also be automatically every second time the measuring and data recording, press the MODE key to switch a single measurement and automatic Measurement
7. Statistics: Press REC button, you can display the recorded data of the maximum value (MAX ) Minimum (MIN ) Average (MEA)
8... Instruments amended: according to the measurements needed, users can select their own criteria for data correction, testing criteria, and then press the ' + ' '-' keys to adjust the data to, the instrument automatically saves data
9. Restore factory settings: turned on press and hold the MODE button down for 5 seconds, the instrument automatically after reboot rings twice in a row, said the operation was successful