Product parameters:
- Customized processing: no
- Type: digital current measurement instruments
- Brand: meet macros
- Model: AT573
- Measuring range: -10A-10A
AT573 DC bias current source
AT573 DC bias current source (DC magnetization power bias current source) is used for inductors and transformer windings inductance measurement applying DC bias current, this device apart from the need to achieve the required current, also small impact on the measurement of inductance, wide frequency response (superimposed DC current can be used when high-frequency LCR Meter measurement) and other requirements. AT573 DC bias current source with color vacuum VFD Display, controlled by microprocessor, working parameters automatically memory. Automatic current balanced principles to achieve the stability of AC-DC superposition of current, constant current output with forward or reverse 0-10A range. Additional errors the product, frequency response to be increased substantially, greatly expanded a magnetic core inductor applications in bias test range. Directly controlled by Amber AT2818,AT2816A,AT2816B,AT2817A,AT2817,AT810A digital bridges and more current scan output functions, provide a good solution for the analysis of magnetic materials.
| Technical specifications |
| ● | Current range -10A-10A (200mA/2A/10A | | ● | Current reading accuracy ± 1% ± 3 words | | ● | Current resolution 200mA ranges: 0.1 mA, | | ● | 2 a ranges: 0.1 mA, | | ● | 10A-range: 10 mA | | ● | Current output type single point output, more output shared output | | ● | Frequency response 50 Hz-200kHz | | ● | L ﹤ 2 k ω resistance range ω and l ﹤ 8/I (h), output current I | | ● | Output voltage 0-8 v | | ● | Basic impedance accuracy ≤ 1% | | ● | Scanning mode manually, automatic (Flyback) | | ● | Points 2-15 points | | ● | Set delay time 0-99 seconds | | ● | Warm-up time 20 minutes |
|
| Performance characteristics |
| ● | Four color vacuum fluorescent display VFD | | ● | Direct current is controlled by the AT2818,AT2816A,AT2816B,AT2817A,AT2817,AT810A automatic or manual scanning output | | ● | Long time high current output | | ● | User data automatically saved | | ● | Frequency response range: 50Hz-20KHZ low additional error, wide frequency response range | | ● | Single point, multi-point scanning, equal parts scanned three current output | | ● | 0-99s delay time setting | | ● | RS232 interface | | ● | Shock protection, prevent damage to LCR tables | | ● | Single output current reverse switch, adjustable current | | ● | Desirable/shared scans, with Flyback function, manual/auto scan | | ● | Working parameters automatically memory | | ● | Operating 0~40℃, ﹥ internal overheating temperature 70 ℃, humidity 20~80%RH |
|