Product parameters:


Technical specifications
Function | AC leakage current measurements; Online monitoring, recording |
Power supply | Alkaline dry battery LR6 DC6V 1.5Vx4 |
Test mode | Flexible CT: the output signal is a current differential of time, through integration of the output voltage, you can actually restore the input current. |
Coil diameter | Inner diameter of 300mm |
Range | AC 0.00A~ 20.00kA |
Resolution | AC 10mA |
Precision | ± 2% ± 3dgt (flexible coils of wire in a central location, 23 ℃ ± 2 ℃) |
Coil length | Length of 1000mm |
By measuring current frequency | 50Hz/60Hz (automatic identification) |
Display mode | LCD: 128dots×64dots |
Host size | Width thickness 75mmx170mmx30mm |
Coil weight | 7.5mm (is perfect for narrow environment and line-intensive sites, etc) |
Quality | Host: 240g (including battery); Flexible clamp: 150g |
LCD size | Display field: 44mmx27mm |
Electric field interference | No hysteresis, strong anti-jamming ability |
Position error | Flexible coil of wire to be measured should be in central position, not near the mouth of the opening and closing, opening and closing of entrance test error of about 1 time or more. |
Sample rate | 2 times/second |
Data storage | 4200 Group (power off or change batteries without losing data) |
Set the time | 1~ set the logging interval within 60 minutes of the time 0 minutes to not automatically store |
Recording time | Power save mode approximately 100 hours of continuous operation |
Line voltage | AC600V the following line tests |
Overflow display | Overrange overflow feature: 'OL ' Symbol appears |
Battery voltage | When the battery voltage drops to 4.8V ± 0.1V, low battery voltage symbol appears, reminding to replace the battery, time measurements are accurate. |
Rated current | Power-saving mode 5mA, MAX 20mA |
Lead length | Standard 2 m |
Working temperature and humidity | -10 ℃ ~ 40 ℃; 80%RH the following |
Storage temperature and humidity | -10 ℃ ~ 60 ℃; 70%RH the following |
Insulation resistance | 100M ω or greater, 1000V |
For safety | IEC1010-1, IEC1010-2-032, pollution level 2, CAT VI (1000V) IEC61326 (EMC standard) |
Supplied accessories | Host: 1; Flexible coils: 1; RS232 communication lines: one; Software CD: one; Battery LR03:4; Bag: 1 PCs |