Product parameters:


Product description
ETCR300F Flexible coil transducer , That is, Rogowski Coil(Rockwell coil )Using advanced coil technology, is a non- Ferromagnetic Material evenly wound toroidal coil, no Hysteresis Almost zero phase error, no Magnetic saturation , And high linearity. Output signal is a current differential of time, through integration of the output voltage, you can actually restore the input current, measuring current can range from Ma levels to tens of thousands. Mainly used in AC leakage current, high current, high harmonic current (Up to 400Times )Complex waveform currents and transient impulse current, phase, power, power, power factor testing. Matching Integrator, easy to integrate into other devices such as phase detection of analyzers, industrial control equipment, data recorders, Oscilloscopes, harmonics Analyzer, power quality Analyzer, high precision digital multimeters, transient impact recorders, distributed measurement systems, protection systems, and so on.
ETCR300F Flexible current sensors Coil without any exposed metal conductors, non contact measuring, safe and reliable; Its small size, light weight, attractive appearance, soft and flexible, Suitable for narrow environment and line-intensive sites ; Wide measuring range, high accuracy, high reliability and frequency response bandwidth (0.1Hz-1MHz), Users can be customized according to the needs the stitch length. Widely used in electric power, communication, meteorological, railways, oil field, construction, measurement, research and teaching units, industrial and mining enterprises, and other fields. Particularly suitable for Relay protection , Silicon controlled Rectifier , Inverter, semiconductor switches, power electronic conversion devices ARC Welding Serious distortion of signals, such as industrial environments.
Technical specifications
Function | AC leakage current, high current, high harmonic current, Complex waveform currents and transient current Phase, power, power, power factor testing |
Detection methods | Flexible CT: Output signal is a current differential of time, through integration of the output voltage, you can actually restore the input current |
Coil length | 1000mm (Can be customized according to needs) |
Coil diameter | 300mm (can be customized according to needs) |
Coil diameter | 7.5mm (is perfect for narrow environment and line-intensive sites, etc) |
Quality | 150g |
Range | 0A~ 10000A~ more |
Resolution | 10mA |
Accuracy grade | ± 1.0%FS (50Hz/60Hz; 23 ℃ ± 2 ℃, 70%RH, wire coil Center) |
Phase error | ≤0.1°(50Hz/60Hz; 23℃±2℃) |
Output interface | 3.5mm Audio rate plug |
Output cord length | 2m |
Electric field interference | No Hysteresis Without external Electric field Hinder |
Wire location | Central location test wire in a coil, position error ≤ ± 0.3%FS |
Current frequency | 45Hz ~ 70Hz (current frequency to be measured) |
Response frequency | 0.1Hz ~ 1MHz |
Line voltage | AC 1000V Following line tests |
Working temperature and humidity | -20℃-50 ℃; 80%RH the following |
Storage temperature and humidity | -10℃~ 60 ℃; 70%RH the following |
Dielectric strength | AC 2000V/rms(Both ends of the coil) |
For safety | IEC1010-1, IEC1010-2-032, pollution level 2, CAT IV 1000V |
Supplied accessories | Sensor: 1 |
Structure size