Product parameters:


Function | Electrical power for simultaneous measurement of oil parameters: AC current, voltage, frequency, phase voltage and current, breaking resistance value Pumping up and down stroke of the maximum current, Lack of rushing, stroke up and down time, and number of strokes per minute |
Power supply | DC7.2V (1.2V 6, 5th rechargeable Ni-MH batteries 1200mAH) |
Range | Voltage: AC 0V~ 700V |
Current: AC 0.0mA~ 300A | |
Phase: 0 ° ~ 360 ° | |
Resistance: 0.00Kohm~ 20.0Kohm | |
Frequency: 10.0Hz~ 70.0Hz | |
Resolution | Voltage: AC 1V |
Current: AC 0.1mA | |
Phase: 1 ° | |
Resistance: 10ohm | |
Frequency: 0.1Hz | |
Precision | Voltage: ± (1.5%RDG+3dgt) |
Current: ± (1.5%RDG+3dgt) | |
Phase: ± 3 ° | |
Resistance: ± (2.0%RDG+3dgt) | |
Frequency: ± (2.0%RDG+3dgt) | |
Measured phase frequency amplitude | Voltage: 30V~ 700V |
Current: 30mA~ 300A | |
Appearance quality | 1kg (with attachments) |
Meter size | Length thickness: 196mmx92mmx54mm |
Jaw size | Round shape current clamp: 35mmx40mm |
Detection Rate | About 2 seconds/second |
Display mode | LCD Show 240dotsx160dots |
Number number | 100Number |
Number sets | 15Code that can be edited by instrument or PC software |
Data storage | 1000Group |
Clock function | Have |
Password settings | There, the 6-digit password |
Backlight function | , Suitable for use in dark places and in the evening, do not operate the instrument will automatically turn off after 3 minutes the backlight |
Automatic shutdown | Boot operation within 15 minutes upon the instrument will auto power off |
Battery voltage | Instrument time display battery voltage when battery voltage is less than 6.5V, and low battery voltage symbol appears, please recharge the |
Communications interface | USB Interface, data kept by computer, to facilitate the analysis of management data through software editing |
Communication line | USB Communications cable, 1.8 m |
Test length | 1.5m |
Current clamp cord length | 2m |
Working temperature and humidity | -20℃~ 40 ℃; 80%Rh the following |
Storage temperature and humidity | -10℃~ 60 ℃; 70%Rh the following |
Input impedance | Test voltage input impedance: 1M |
Pressure resistance | Meters between shell and tolerance 1000V/50Hz sine wave AC voltage 1-minute |
Insulation | Between meters and sheathed the shell 100M ω |
Structure | Double insulation with Insulation vibration-proof sheath |
For safety | IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution level 2 |
Power consumption | Backlight turn on maximum power consumption 50mA |
The backlight turn off instrument power consumption 30mA | |
Supplied accessories | Host: 1; Current clamp: 1; Test line: 4; USB Cable: 1; Software CD: one; Enclosures: 1 PC ; Charger: 1; Rechargeable battery: 6 (1.5V, 5th) |