Product parameters:
Model | Introductions | Range | Resolution | Jaw size |
| ETCR9000 | Base type | 0.0mA-1000A | 0.1mA | φ48mm |
| ETCR9000B | Wireless transmission | |||
| ETCR9000S | Portable | |||
| ETCR9100 | Base type | 0.00mA~ 600A | 0.01mA | φ33mm |
| ETCR9100B | Wireless transmission | |||
| ETCR9100S | Portable | |||
| ETCR9200 | Large diameter Foundation | 0.00mA~ 1000A | 0.01mA | φ68mm |
| ETCR9200B | Large-caliber wireless transmission |
Function | Measurement of high-voltage alternating current, low-voltage AC current, leakage current measurement, online current monitor |
Power supply | DC6V alkaline dry battery (1.5V AAAx4) |
Test mode | Clamp CT, integral way; Instruments can be hung on the line tests, saves the operator manual. |
Jaw size | φ68mm |
Measuring range | 0.00mA~ 1000A (50Hz/60Hz Auto) |
Resolution | 0.01mA |
Shift | 0.00mA~ 1000A automatic shift |
Test accuracy (23 ℃ ± 5 ℃, 80%RH) | 0.00mA~ 299mA:±1%±3dgt |
| 0.30A~ 49.9A: ±1.5%±5dgt | |
| 50.0A~ 199.9A: ±2%±5dgt | |
| 200A~ 600A: ±3%±5dgt | |
| 601A~ 1000A: ±4%±5dgt | |
Display mode | 4-digit LCD display |
LCD size | Detector LCD:35mmx21.5mm |
Meter size | Tester: 218mmx135mmx60mm |
Sample rate | 2 times/second |
Data storage | 99 groups stored procedure 'MEM' Symbol indicates, 'FULL ' Symbol flashes, said store is full |
PEAK stay | Automatically keep the upper test value, usually test mode PEAK Key, right corner of the LCD displayPE ' Symbol, the opening PEAK hold function, press PEAK To cancel this feature |
Line voltage | 60kV insulation sheath wire tests below 35kV bare wire tests (with insulated Rod operation) |
Data retention | Usually test mode HOLD -Keeping the data, 'DH ' Symbol appears, and then press HOLD Key to cancel |
Data access | 'MR ' Symbol indicates, above and below to read the data stored |
Overflow display | Overrange overflow feature: 'OL A ' Symbol appears |
Automatic shutdown | Power on after about 15 minutes, the instrument automatically shutdown to reduce battery consumption |
Battery voltage | When the battery voltage is less than 4.8V, and low battery voltage symbol ' ' appears, reminding battery replacement |
Appearance quality | Tester: 620g (with battery) Instrument mass: 2.3Kg (with insulated rods and battery) |
Working temperature and humidity | -10 ℃ ~ 40 ℃; 80%Rh the following |
Storage temperature and humidity | -10 ℃ ~ 60 ℃; 70%Rh the following |
Hinder | No 315MHz, 433MHz co-channel interference |
Insulated bar size | 32mm, 1M/(5) |
Dielectric strength | Detector: AC 2kV/rms (between shell and screws) Insulation: AC 100kV/rms (section 5 insulation all connections, between the ends) |
Structure | Drip-proof type |
Supplied accessories | Gauge: 1; Instrument packages: 1; Insulated rod (1 m): 5; Battery (alkaline battery LR03): 4 |