Product parameters:


1. Baseline condition and working condition
Influence quantity | Baseline condition | Working conditions | Notes |
Ambient temperature | 23℃± 1 ℃ | -10℃~ 40 ℃ | ---- |
Environment humidity | 40%~ 60% | < 80% | ---- |
Signal waveform | Sine wave | Sine wave | β=0.01 |
Signal frequency | 50HZ ±1HZ | 45HZ ~ 65HZ | ---- |
Meter operating voltage | 9V±0.1V | 9V±1.5V | ---- |
When measured phase frequency phase sequence Current amplitude | 200mA ±3mA | 2mA~ 20A | ---- |
When measured phase frequency phase sequence Voltage amplitude | 100V±10V | 10V~ 600V | ---- |
When measuring the power factor Current amplitude | 200mA ±3mA | 20mA~ 20A | ---- |
When measuring the power factor Voltage amplitude | 100V±10V | 10V~ 600V | ---- |
Electric field, magnetic field | You should avoid | ||
Test wire location | The approximate geometric center of the conductor to be measured in the jaw position | ||
2. Basic errors under baseline conditions and performance indicators
Category | Range | Resolution | Basic errors |
Voltage | AC 0.00V~ 600V | 0.01V | ± (0.5% range) |
Current electricity | AC 0.0mA~ 20.0A | 0.1mA | ± (0.5% range) |
Phase | 0.0° ~ 360 ° | 0.1° | ± 1 ° |
Active power p | 0.0W~ 12kW | 0.1W | ± (1% range) |
The reactive power Q | 0.0VAR ~ 12kVAR | 0.1VAR | ± (1% range) |
Apparent power s | 0.0VA ~ 12kVA | 0.1VA | ± (1% range) |
Power factor PF | -1~ +1 | 0.001 | ± 0.03 |
Frequency f | 45HZ ~ 65HZ | 0.01HZ | ± (1% range) |
Work under the conditions of phase error: 10mA~ 20A ± 3 °; 10mA ± 6 °
3. General specifications
Function | Simultaneous measurement of two AC voltage and current, the voltage between phase and phase between the current, voltage and current phase, frequency, phase sequence, active power, reactive power, apparent power, power factor, judging transformer, inductive, capacitive circuits Test secondary circuit and differential protection system, read the travel protection group CT The phase relationship between, check the meter's wiring is correct or not, inspection line equipment |
|
Power supply | DC9V Alkaline dry batteries (1.5V AAx6) |
|
Range and resolution | Voltage range: AC 0.00V~ 600V; Resolving power: AC 0.01V | |
Current range: AC 0.0mA~ 20.0A; Resolving power: AC 0.1mA | ||
Phase measuring range: 0.0 ° ~ 360.0 °; Resolution: 0.1 ° | ||
Frequency range: 45.00Hz~ 65.00Hz; Resolution: 0.01Hz | ||
Power range: 0.0W~ 12kW; Resolution: 0.1W | ||
Power range: 0.0VAR~ 12kVAR; Resolution: 0.1VAR | ||
Apparent power range: 0.0VA~ 12kVA; Resolution: 0.1VA | ||
Power volume range: -1~ to +1; Resolution: 0.001 | ||
Appearance quality | 1170g(With battery) | |
Meter size | Length thickness: 196mmx92mmx54mm | |
Jaw size | Current clamp: 35mmx40mm | |
Detection Rate | About 2 seconds/second | |
Display mode | LCD Show 240dotsx160dots | |
Data storage | 1500Group | |
Data retention | Testing press HOLD -Keeping the data, 'HD ' Symbol appears | |
Automatic shutdown | Power on after about 15 minutes, the instrument automatically shutdown to reduce battery consumption | |
Backlight function | Suitable for dark places and night use | |
Voltage detection | When the battery voltage is less than 7.2V, and low battery voltage symbol appears, reminding battery replacement | |
Communications interface | USB Interface, data kept by computer, to facilitate the analysis of management data | |
Test length | 1.5m | |
Current clamp cord length | 2m×φ5mm | |
Working temperature and humidity | -10℃~ 40 ℃; 80%Rh the following | |
Storage temperature and humidity | -10℃~ 60 ℃; 70%Rh the following | |
Input impedance | Test voltage input impedance: 1M | |
Pressure resistance | Meters between shell and tolerance 1000V/50Hz sine wave AC voltage 1-minute | |
Insulation | Between meters and sheathed the shell 100M ω | |
Structure | Double insulation with Insulation vibration-proof sheath | |
For safety | IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution level 2 | |
Power consumption | Turn on backlight lamp maximum power consumption 70mA battery 8 hours of continuous operation | |
Turn off backlight instrument power consumption 40mA battery work 120 hours | ||
Supplied accessories | Host: 1; Current clamp: 2; Test line: 4; USB data cable: 1; Software CD: 1; Battery LR6:6; Enclosures: 1 PC | |