Product parameters:
Product number: BZY-B (platinum ring method)
Product name: automatic surface /Interface tensiometer
Product features:
1.Platinum ring principle;
2.Manual control lifting;
3.Peak automatically;
4.Ching Cheng 0, a key to complete, instant zero, stable zero drift-free;
5.Fully automatic range correction data is accurate and reliable, excellent repeatability;
6.Displays the value for the sample values, through converted into surface tension calculation software (free software), or buy data processing software to automatically calculate;
7.Can accurately test the different Interfacial tension of a liquid, such as oils /Water interface;
8.Platinum ring wire RADIUS 0.185mm , RADIUS 9.55mm Ring circumference 60mm;
9. Fully comply with the following national and international standards:
GB/T 22237-2008 Surface active agents Determination of surface tension
JB/T 9388 - 2002 Interfacial tension meter specification
JB/T 18396-2001 Natural latex Loop method for determination of surface tension
SH/T 1156-95 Synthetic LaTeX Method for determination of surface tension
GB/T 6541 - 86 Method for determination of oil-water Interfacial tension of oil products (ring)
ISO 1409-1995 Plastic, rubber, polymer dispersions and LaTeX-determination of surface tension
ISO 6295-1983 Petroleum products Mineral oil Oil-water Interfacial tension measurement (ring)
GB/T 5549(ISO304-1985)Determined by pulling up on the membrane surface tension
As well as the ISO14090-82, ASTM D1417, EN14370, ZB2025-93, GB2960-82, GB6541-86Standard
10.Reasonable structure, working independently, without any additional equipment (such as add-ins computer);
11.Test data are available through RS232C Output
12.Can completely replace analog mechanical surface tension instrument
13. this platform series instruments in addition to the manual control sample landing and taking off, similar to the main structure, technical parameters and QBZY series, High quality design, cheap price, price high
Main technical parameter:
Test mode |
Platinum ring |
Mode of operation |
Sample manual lifting, automatic measurement |
Test ranges |
0- 600mN/m |
Sensitivity |
0.1 mN/m |
Measurement accuracy |
± 0.1 mn/m (test 20 ℃ 2 distilled water, and the literature value of error) |
Repeatability |
± 0.1 mn/m (test 20 ℃ 2 distilled water, and the literature value of error) |
Data display |
Wide viewing angle LCD display and conversion |
Sample temperature range |
0~ 100 c (requires optional thermostat and heated pool) |
Measuring time |
Measurement of low concentration of the sample solution in 30-90 seconds |
Container constant |
At least 15ml |
Data output |
RS 232C matching serial or USB data interface |
Power supply |
Power AC220V, 1A |