Product parameters:
Product name: United States import milk somatic cell Tester
Type of the products: SCC Digital Reader
Configuration: Cell Tester * 1, strips * 100, zero strips * 2, the Activator * 1 bottle, dropper, 10 color card * 1, * 1 of the manual
The "about us" United States imports SCC Digital Reader milk somatic cell detector is to introduce United States early mastitis Diagnostics patented technology PortaCheck technology company, by detecting the early prevention of mastitis in dairy cows milk somatic cell.
"Product brief"United States imports SCC Digital Reader milk somatic cell detector can be used to estimate the somatic cell count in milk, SCC Digital Reader milk somatic cell detector has been in the United States and Canada the assessment had been conducted at the University, and laboratory testing concluded that there is a good linear correlation of the data. United States imports SCC Digital Reader milk somatic cell detector detection principle is based on tests of dyes and milk the enzyme reactions in the cell, the chemical reaction enables the test strip to turn blue, darker, indicating higher somatic cell count. United States imports SCC Digital Reader milk somatic cell Tester readings in two ways: 1 with color control card, quick milk somatic cell count ranges. 2 use the SCC Digital Reader readout, and specific values. "Parameters"
"Scope of application"
Used for pasture, dairy, such as Recycle Bin, testing the milk quality, early to judge hidden mastitis in dairy cows and monitor the treatment of diseased cattle.
"Product features"
1 portable for outdoor scene detection.
2 accurate, relevant, reduce milk, reduce the incidence of mastitis.
3 fast, finished 1 minute, 45 minute can produce concrete results.
4 economics, low equipment prices, suitable for use in pasture and cattle herders.
5 simple fool-simple, no professional action.
"How-to"



1 mix the milk sample 2 vertical drop milk samples on the test hole 3 Add 3 drops of Activator


With a shade after 4 wait for 45min or instrument readings 5 Use shade or instrument readings
"Considerations"
1, milk samples should be 8 hours out of fresh milk and frozen milk samples to be restored to room temperature;
2, do not put before the test strip is wet;
3, do not bend or disassemble paper components, touch the hole, avoid exposure to fine dirt in the hole;
4, avoid direct sunlight or extreme temperatures;
5, environmental temperatures between 7 c to 35 c test is the best;
6, testing milk samples cannot be mixed with things like preservatives, BRONOPOL, etc;
7, activator for chemicals, don't drink;
8, dropper reusable, fully squeeze the last remaining milk, second in milk or water squeezed repeatedly 3-4;
9, test strips, activator, 2 ℃ than the color cards ~ save 25 deg c away from light and dry.
10, best used within 4 hours after the package apart.
