Low Frequency Online UPS (TA 2K-20K)

Low Frequency Online UPS (TA 2K-20K)

bargain

add to cart
Model NO. Low Frequency Online UPS (TA 2K-20K)
Type On-line
Application Industry
Standby Time Long-acting Machine
Output Capacity Large Type
Brand Kemapower
Specification ISO / CE / UL
Phase Three Phase
Protection Short Circuit
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Decentralized
Trademark KEMAPOWER
Origin China
1. Single phase in, single phase out
2. Microprocessor control
3. True on-line double conversion design
4. Sine wave pulse width modulation.
5. Isolated output
6. IGBT inverter design
7. Wide Input voltage windows
8. Pure sine wave output with less than 3% THD
9. Expandable backup time
10. Generator compatible
11. Cold start
12. Load/Battery power meter display
13. Overload, on-line, battery status LED/LCD
14. Advanced Battery Management
15. Automatic charging in UPS off mode
16. Zero transfer time
17. Smart RS-232 communication port
18. Optional SNMP card
Capacity:
* TA2kVA/1.6KW/192VDC/6A
* TA3kVA/2.4KW/192VDC/6A
* TA4kVA/3.2KW/192VDC/6A
* TA6kVA/4.8kw 192VDC/6A
* TA8kVA/6.4KW/ 192VDC/6A
* TA10kVA/8KW/ 192VDC/6A
* TA12kVA/9.6KW/ 192VDC/6A
* TA15kVA/12KW/192VDC/6A
* TA20kVA/16KW/192VDC/6A
(10AMP is optional)
Input:
* 220V/110V
Output;
* 220V/110V
Wave Form;
* pure sine wave.
MODEL TA2K TA3K TA4K TA6K TA8K TA10K TA12K TA15K TA20K
Power capacity 2KVA 3KVA 4KVA 6KVA 8KVA 10KVA 12KVA 15KVA 20KVA
1.6KW 2.4KW 3.2KW 4.8KW 6.4kW 8KW 9.6KW 12KW 16KW
Input Voltage Range 220V or 110V+-20%
Frequency 50/60Hz±5%lusmn;5%lusmn;5%
Phase Single phase + GND
Output Voltage Range 220VAC ±1% or 110VAC ±1%0VAC ±1%usmn;1%0VAC ±1%
Frequency 50/60Hz ± 0.3%mn; 0.3%mn; 0.3%
Phase Single phase + GND
THD < 3% (linear load), < 5%( nonlinear load)r load)
Power Factor 0.8
Short Circuit Protection Current limit, turn off automatically, Switch protect
Overload Capacity Overload 125% for 10 Mins, 125%-150% for 30s .automatically resume when load become
normal
Battery Type Sealed lead acid, maintenance free
DC Voltage 48VDC 96VDC 192VDC
Charge current 6A 6A 6A 6A 6A 6A 6A 6A 6A
Panel indication LCD Input,oupt,battery voltage,frequency,load rate,UPS state, temperature
LED Main input , bypass,Inverter,Battery,Over load,Fault
Efficiency Whole unit 85%
Communication 1.Power status 2.UPS shutdown 3.monitor UPS status 4.UPS self test 5.auto-save files
Protection Surge Protection IEEE527B
Noise FCC.A
Audible Noise <55db (at 1 meter)ter)
Environment Temperature 0--40 ºCordm;Cordm;C
Humidity 0%-95%