Line Interactive off Line UPS (AT500-AT1200)

Line Interactive off Line UPS (AT500-AT1200)

20-40 USD

add to cart
Model NO. AT500-AT1200
Type Line Interactive
Trademark KEMAPOWER
Origin China
Phase Single Phase
Protection Short Circuit
Specification AT500-AT1200
Line Interactive Off Line UPS (AT500-AT1200)
* I/P: 220VAC or 110VAC , O/P:220VAC or 110VAC ± 10%usmn; 10%smn; 10%
* Capacity:500VA / 600VA / 800VA /1KVA /1.2KVA/1.5KVA
* Output PF: 0.6
* Wave Form:Modified sine wave
* Transfer Time:<10 ms10 ms
* DCVoltage:500VA /600VA /800VA /12VDC ,1KVA,1.2KVA/1.5KVA/24VDC
* Bat.:500VA / 600VA:1PCS 7.2AH, 800VA:1PCS 9AH,1KVA /1.2KVA/1.5KVA:2PCS 7.2AH

Key features:
1. Wide input voltage window
2. Boost and Buck AVR
3. Protection for short circuit, overload and battery low voltage
4. LED indication and audible alarm function
5. Intelligent battery management
6. AUTO start function is option
7. Automatic battery charging in UPS off mode ( Option)
8. Cold start function
9. RJ11/RJ45 is option
10. dB9 is option
Capacity:
* AT500/500VA/300W
* AT650/650VA/390W
* AT800/800VA/480W
* AT1000(1kVA/600W)
* AT1200(1.2kVA/720W)
* AT1500(1.5kVA/900W)
Input:
* 110V or 220V +- 20%
Output;
* 110V or 220V+ - 10%
Wave form:
Transfer time less than 10Ms.
ITEM MODEL AT 500 AT 650 AT 800 AT 1000 AT 1200 AT 1500
Capacity Output power 500VA/300W 650VA/390W 800VA/480W 1000VA/600W 1200VA/720W 1500VA/900W
Input Voltage range 165~275Vac±5V (140--280v is option ) or 88 - 139Vac- 139Vac- 139Vac
Frequency range 50 or 60 ± 2.5Hzn; 2.5Hzn; 2.5Hz
Output Voltage (battery mode) 220V or 110V ± 10%smn; 10%smn; 10%
Frequency (battery mode) 50 or ± 6Hzsmn; 6Hzsmn; 6Hz
Transfer time <10Ms10Ms
Waveform Modified sine wave (battery mode)
Battery Type Sealed lead acid, maintenance free
DC voltage 12VDC
Battery number 1*12V/7AH 1*12V/9AH 2*12V/7AH 2*12V/7AH 2*7.2AH
Low battery voltage protection 9.5V or 10V.
Standby time Full load ﹥3min,half load ﹥8mingt;8min
Recharge After fully discharged, charge 8 hours to 90% capacity
Protecting Output overload Fuse & current limited when overloadedoadedoaded
Battery low voltage Automatically lock out the machine so as to protect the Battery from over discharging
Short circuit Fuse & current limitedmitedmited
Restart Auto restart when AC recovery.
Alarm Battery back-up Sounding every 4 seconds
Battery low Sounding every 1 second
Overload Shutdown at once
Indicator LED LED indicator for line on, battery back-up, UPS cut-off
Package size L*W*H(mm) 2PCS 590*315*240 385*315*235 400*315*335 480*405*290 480*405*290 480*405*290
Package weight Kg, 2PCS 9 11 13.4 19.6 19.6 19.6