| Model NO. | Ri19-Pro |
| Certification | CE, IEC,EMC,LVD |
| Grid Type | off-Grid Inverter |
| Circuit Topologies | Full-Bridge Type |
| Type | DC/AC Inverters |
| Output Frequency | 50Hz/60Hz +/-0.5 Hz |
| Certificate | Ce,LVD,IEC,ISO9001 |
| Frequency | High Frequency |
| Trademark | Richwin/OEM/ODM/Neutral |
| Specification | 319*328*123mm |
| HS Code | 850440994 |
| Nature of Source Flow | Passive inverter |
| Output Power | 1.2kVA-2.4kVA |
| Output Type | Single |
| Nature of Wave String | Square Wave Inverter |
| Input Voltage | Input Voltage: 230VAC/170-280VAC/ 90-280VAC |
| Transfer Time | 4ms Typical, 8ms Max. |
| Rated Power | 1.2kVA-2.4kVA |
| Input Range | 90-280VAC |
| Transport Package | Carton/Wooden |
| Origin | Shenzhen, China |


| MODEL | RI19-1200Pro | RI19-1800Pro | RI19-2400Pro | ||
| Default Battery System Voltage | 12VDC | 12VDC | 24VDC | ||
| INVERTER OUTPUT | Rated Power | 1200VA/720W | 1800VA/1000W | 2400VA/1440W | |
| Waveform | Modifided Sine-wave | ||||
| Nominal Output Voltage RMS | 230V | ||||
| Output Voltage Regulation | +10/-18% | ||||
| Output Frequency | 50Hz/60Hz +/-0.5 Hz | ||||
| Inverter Efficiency(Peak) | >80% | ||||
| Line Mode Efficiency | >95% | ||||
| Power Factor | 0.6 | ||||
| Typical Transfer Time | Typical 15~20ms 40ms max | ||||
| AC INPUT | Voltage | 230VAC | |||
| Selectable Voltage Range | Narrow | 170~280VAC | |||
| Wide | 90~280VAC | ||||
| Frequency Range | 50Hz/60Hz (Auto sensing) | ||||
| BATTERY | Nominal Input Voltage | 12VDC | 24VDC | ||
| Minimum Start Voltage | 10.5VDC | 21.0VDC | |||
| Low Battery Alarm | 10.5VDC+/-0.3V | 21.0VDC+/-0.3V | |||
| Low Battery Cutoff | 10.0VDC+/-0.3V | 20.0VDC+/-0.3V | |||
| High Voltage Alarm | 16.0VDC+/-0.3V | 32.0VDC+/-0.3V | |||
| High Battery Voltage Recover | 15.0VDC+/-0.3V | 30.0VDC+/-0.3V | |||
| CHARGER | Charger Voltage (Vbat<12.5V).5V) | 14.4VDC+/-0.4V | 28.8VDC+/-0.4V | ||
| Charger Voltage (Vbat﹥12.5V).5V) | 13.7VDC+/-0.2V | 27.4VDC+/-0.2V | |||
| Charging Current 10A | 10A±2Alusmn;2Alusmn;2A | ||||
| Charging Current 20A | 20A±2Alusmn;2Alusmn;2A | ||||
| Overcharge Protection S.D. | 16VDC ±0.4Asmn;0.4Asmn;0.4A | 32VDC ±0.8Asmn;0.8Asmn;0.8A | |||
| BYPASS & PROTECTIONCTIONCTION | Nominal Input Frequency | 50Hz or 60Hz | |||
| Overload Protection (SMPS Load) | FUSE | ||||
| Output Short Circuit Protection | FUSE | ||||
| Bypass Fuse Rating | 10A | ||||
| Max Bypass Current | 10Amp | ||||
| MECHANICAL SPECIFICATIONS | Dimensions (W*H*D) | 253*267*90mm | |||
| Net Weight (kg) | 2.3 | 2.5 | |||
| Shipping Dimensions(W*H*D) | 319*328*123mm | ||||
| Shipping Weight (kg) | 2.9 | 3.1 | |||
| OTHER | Operation Temperature Range | 0°C to 40°C 40°Ceg;C 40°C | |||
| Audible Noise | 60dB MAX | ||||
| Display | LED+LCD | ||||
| Standard Warranty | 1 year | ||||
| Loading(20GP/40GP/40HQ) | 1800pcs / 3600pcs / 4200pcs | ||||
| Power Rate(w) | backup time(H) @1*100Ah | backup time(H) @2*100Ah | backup time(H) @4*100Ah | backup time(H) @4*200Ah |
| 720 | 1.4 | 2.8 | 5.6 | 11.2 |
| 1000 | 0.9 | 1.9 | 3.8 | 7.5 |
| 1400 | 1.4 | 2.8 | 5.6 |