Low Frequency Online UPS (TC10K-120K)
* I/P: 220VAC or 110VAC,O/P:220VAC or 110VAC ± 1%lusmn; 1%usmn; 1%
* Capacity:2K/3K/4K/6K/8K/10K/12K/15K/20KVA
* Output PF: 0.8
* Pure sine wave
* Transfer Time:0 ms
* DC Voltage: 2KVA:48VDC,3KVA:96VDC,6/8/10/12/15/20 KVA:192VDC
* Bat.:External Batterys
* Charge Current: 6A
Key feature:
1.Three phase in, three phase out
2.Microprocessor control
3.100% unbalance protection design
4.True on-line double conversion design providing all power protection
5.Isolated output
6.Sine wave pulse width modulation
7.IGBT inverter design.
8.Wide Input voltage windows
9.Pure sine wave output less than 3% THD
10.Expandable battery run time
11.Generator compatible
12.Cold start
13.Load/Battery power meter display
14.Overload, on-line, battery status LED/LCD
15.Advanced Battery Management
16.Automatic charging in UPS off mode
17.Smart RS-232 communication port
18.Optional SNMP card
| Technical Specifications |
| MODEL | TC10K | TC15K | TC20K | TC30K | TC40K | TC60K | TC80K | TC100K | TC120K |
| Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA |
| Power | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW |
| Power Factor | 0.8 |
| Input | Phase | 3 phase 4 wire and ground |
| Voltage Range | 380V±20%(3 phase), phase voltage 220Vage 220Vage 220V |
| Frequency Range | 45 - 65Hz |
| Rectifier | 3 phase 6 pulses, 12 pulses is optional |
| Output | Phase | 3 phase 4 wire and ground |
| Wave form | Pure sine wave |
| Crest Factor | 3:01 |
| Rated voltage | 380/400/415V optiona+ -1% for static load, 5% forfluctuant load |
| Phase voltage setting | 200 - 244VAC, pls confirm when order |
| Transient response | +/-5%, 10ms |
| Frequency | 50 / 60 Hz + / - 0.05% |
| Total harmonic distortion | < 3%(linear load, < 5%( nonlinear load)r load) |
| Short circuit current | Short current for 0.1s (200% current) |
| Overload capacity | Overload 125% for 10 Mins, 125%-150% for 1min .automatically resume when load become normal |
| Battery | Battery | Maintenance free lead-acid cell |
| DC Voltage | 384VDC | 396VDC |
| Max Charge Current | 6-30A adjustable |
| Bypass | Type | Static state + manual maintenance bypass |
| Input Phase | 3 phase 4 wire and ground |
| Input voltage range | 15% - 25% (the front control panel selectable) |
| Transfer time | Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms |
| Efficiency | Whole unit | >80% |
| Inverter | 91 | 91 | 92 | 92 | 93 | 93 | 95 | 95 | 95 |
| Remote signaling | Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA,Optional parts |
| Communication interface | RS232 ( SNMP , modem optional ) |
| Running temperature | 0-40 degree Celsius |
| Relative Humidity | Less than 95% (without condensing) |
| Noise at 1 M | less than 60 dB |
| Degree of protection | IP20 |
| Applicable Standards | EN50091-1-EMC EN50091-2liv.A |
| Product size(mm) | 780*580*1170 | 1000*660*1450 | 1200*900*1820 |
| product weight(Kg) | 180 | 220 | 250 | 300 | 400 | 470 | 640 | 740 | 740 |
| Package size(mm) | 945*745*1395 | 1135*810*1755 | 1450*1110*1880 |
| Package weight(Kg) | 200 | 270 | 300 | 350 | 480 | 550 | 700 | 800 | 800 |