| Model NO. | PH3000 |
| Phase | Multiple |
| Certification | CE, UL, ISO9001, CCC |
| Type | DC/AC Inverters |
| Circuit Topologies | Full-Bridge Type |
| Model Number | pH3000 Series Inverter |
| Size | 468*297*125mm |
| Displar | LCD Display |
| High Efficiency | 90% |
| Application | Electric Razor |
| Transport Package | Cartons or with Outsides Wooden Rock, 600PCS/20′0′rime;0′ |
| Origin | Shenzhen, China |
| Nature of Source Flow | Active Inverter |
| Output Power | >1000W |
| Brand | Must |
| Power Source | Solar Power |
| Nature of Wave String | Sine Wave Inverter |
| Place of Origin | Guangdong China (Mainland) |
| Output Voltage | 220V 230V 240V Availble |
| Transfer Time | 10ms |
| Input Voltage Range | 184-253V |
| Trademark | MUST or OEM |
| Specification | CE certificates |
| HS Code | 8504403090 |
Model | PH30-3KW | ||
Default Battery System Voltage | 48V DC | ||
Charge | Charge Input | PV Open Circuit Voltage(VDC) | 145 VDC |
Max PV Input Power(W) | 3200W | ||
Storage Battery Voltage | Nominal Voltage(VDC) | 48 VDC | |
Absorption Voltage(VDC) | 54 VDC | ||
Refloat Voltage (VDC) | 54.8 VDC | ||
Float Voltage (VDC) | 57.2 VDC | ||
Low Voltage Protection Point(VDC) | 42 VDC | ||
DC Output | Output Voltage(VDC) | 40 VDC -57.2 VDC | |
Max Charging Current(A) | 60 amps continuous @ 40°C ambientbientbient | ||
Warning for low voltage(VDC) | 46.0 VDC | ||
Cut off for low voltage(VDC) | 42.0 VDC | ||
Low voltage recovery(VDC) | 46.0 VDC | ||
Display | LED indication | Systematic operation, LV indication, LV protection, over charge protection, loads protection, short circuit protection | |
LCD display | Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current | ||
Alarm Protections | PV array short circuit, PV reverser polarity | ||
Battery reverse polarity, Over charging protection | |||
Output short circuit protection | |||
Low voltage protection for storage battery | |||
Charge mode | MPPT, PWM, constant current-constant voltage, function of automatic protection for storage battery | ||
Working mode | Four stage: Absorption CC, Absorption CV, Float CC, Float CV. | ||
Peak Conversion efficiency | 98% | ||
inverter | DC Input | Rated input voltage(VDC) | 48 VDC |
Allowed input DC voltage scope(VDC) | 40 VDC -- 62 VDC | ||
Voltage scope of starting up equipments(VDC) | 46 VDC -- 58 VDC | ||
LV alarm point(VDC) | 42 VDC | ||
OV alarm point(VDC) | 62 VDC | ||
AC Output | Rated capacity(VA) | 3750VA | |
Rated output power(W) | 3000W | ||
Rated output voltage and frequency (Vac/Hz) | 230Vac/50Hz | ||
Rated output current(A) | 13A | ||
Output voltage precision(Vac) | 230 Vac±1%lusmn;1%lusmn;1% | ||
Output frequency precision(Hz) | 50 Hz±0.1%smn;0.1%smn;0.1% | ||
Rate of wave distortion(THD) (Linearity loads) | Off grid≤2%e;2%e;2% | ||
Grid discharge ≤3%e;3%e;3% | |||
Grid charge ≤3%e;3%e;3% | |||
Dynamic response speed(loads 0←→100%)→100%)100%)→100%) | 20ms | ||
Power factor | Grid discharge 99.9% | ||
Grid charge 99.9% | |||
Overload capability | 110%,30 minutes | ||
125%,1 minutes | |||
150%,30 seconds | |||
200%,10 seconds | |||
Short circuit 5s | |||
Grid/Off grid change time | <20ms20ms | ||
Output wave | sine | ||
Inverting efficiency 80% resistive loads | ≥93%;93%;93% | ||
AC Input | AC Input maximum of current(A) | 26A | |
AC Input voltage scope(Vac) | 184Vac -- 253Vac | ||
AC Input frequency scope(Hz) | 47.5Hz -- 51.5Hz | ||
Display | LED indication | Systematic operation, indication of charge and discharge, indication of fault | |
LCD display | output voltage, output current, grid voltage, grid current, voltage of storage battery, load power, chart of capacity | ||
Protection Function | Input LV protection | ||
Input OV protection | |||
Output overload protection | |||
Output Short Circuit Protection | |||
Communication | Communication terminal | RS485/CAN bus | |
Mechanical Specifications | Mounting | Wall mount | |
W*H* D(mm)/G.W(kg) | 337*462*183mm/29.5kg | ||
Other | Operation Temperature Range | -20ºC -- +50ºC +50ºCrdm;C +50ºC | |
Environmental Protection Rating | Indoor(IP20) | ||
Ambient humidity | 0 -- 90% relative humidity(non-condensing) | ||
Altitude | ≤3000m000m000m | ||