1kVA~3kVA Ture Online High Frequency Pure Sine Wave UPS

1kVA~3kVA Ture Online High Frequency Pure Sine Wave UPS

100-300 USD

add to cart
Model NO. T1K~T3KL
Type On-line
Capacity 1kVA~3kVA
Frequency Range 46~54Hz/56~64Hz
Output Power Factor 0.7/0.8
Current Crest Ratio 3:1
Battery Mode Efficiency 83%
Trademark ZLPOWER/OEM
Origin Shenzhen, Guangdong, China
Phase Single Phase
Protection Short Circuit
Nominal Voltage 110V, 120V/220V, 230V, 240V
Input Power Factor 0.97
Wave Form Pure Sine Wave
AC Mode Efficiency 85%
Communication Software RS232
Specification CE, ISO9001, RoHS
HS Code 8504402000
This single phase high frequency online UPS T1K, T2K, T3K is double conversion uninterruptible power supply,
pure sine wave output wave form. It is divided into two models, one is standard online UPS with inside batteries,
the other is long backup time online UPS without batteries.
Application:
Servers, computer data center, critical network devices, sensitive electronic equipment, telecom, smaller lans,
workstation, IPC, small medical equipment, key devices, communication system, some devices need electric power environment.
Main Features:
1. LED Indicators display Detailed Real-Time UPS Status and UPS fault.
2. Advanced MCU microprocessor control technology, ensure long life reliability. 3. Wide input voltage range, Zero transfer time.
4. Excellent Protection against over voltage, over load, over current, over charge and so on.
5. Input L and N lines reverse wiring detection, Auto start when AC back.
6. DC start function, Input PFC revise function.
7. Humanization bypass output can be adjustable.
9. Smart RS232 communication with monitoring software.
10. Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
11. Strong antijamming capability.
12. Available to work with generators.
13. Lightning, surge, short circuit, Network/fax/modem surge protection.
Online UPS MODEL T1K T2K T3K T1KL T2KL T3KL
CAPACITY VA/W 1000VA
/700W
2000VA
/1400W
3000VA
/2100W
1000VA
/700W
2000VA
/1400W
3000VA
/2100W
INPUT Nominal Voltage 110/115/120VAC or 220/230/240VAC
Voltage Range 60~138VAC or 115~300VAC
Frequency Range 50Hz: 46~54Hz; 60Hz: 56~64Hz
Phase Single phase with Ground
Power Factor >=0.97
OUTPUT Voltage 110/115/120*(1±2%)VAC or 220/230/240*(1±2%)VAC1±2%)VAC;2%)VAC1±2%)VAC
Frequency 50/60Hz(Adjustable
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.2%)mn;0.2%)mn;0.2%)
60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%)mn;0.2%)mn;0.2%)
Wave Form Pure Sine Wave
Power Factor 0.7
Harmonic Distortion <3% THD (Linear Load), <7% THD (Non-Linear Load)r Load)
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 200ms
Current Crest Ratio 3:1
Connections IEC320*4 IEC320*6 IEC320*3 & Terminal blockblockblock IEC320*4 IEC320*6 IEC320*3 & Terminal blockblockblock
Efficiency To AC Mode 85%
To Battery Mode 83%
Battery Type Sealed free maintenance lead acid battery
Nominal DC voltage Built in batteries 12v7.2ah 36VDC 96VDC 96VDC
Quantity 3pcs 8pcs 8pcs Depends on requested back-up time
Back-up Time (Full load) ﹥=7 minutesutes ﹥=8 minutesutes ﹥=6 minutesutes Depends on the capacity of external battery bank
Recharge Time 5hours to 90% of capacity full discharge Depends on the capacity of external battery bank
Charge current(MAX) 1.0A 1.0A 1.0A 7A 8A 8A
Charge voltage 41.1Vdc ± 0.6Vmn; 0.6Vmn; 0.6V 110Vdc ± 0.4Vmn; 0.4Vmn; 0.4V 41.1Vdc ± 0.6Vmn; 0.6Vmn; 0.6V 110Vdc ± 0.4Vmn; 0.4Vmn; 0.4V
Bypass Automatic Transfer On overload and UPS failure
Before UPS Power-on Default 'NO' user adjustable to 'YES'le to "YES"t;YES"
Transfer Time 0ms, less than 4ms from inverter to bypass and vice versa
Indicators LCD Display UPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault codeault codeault code
Audible Alarm Bypass, On battery mode, Battery low, Overload, Fault
Acoustic noise At 1 meter distance <45dB45dB <50dB50dB <50dB50dB <45dB45dB <50dB50dB <50dB50dB
Communications Intelligent RS232 serial port Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX and MAC
SNMP (Optional) Remote control UPS through SNMP management and Internet
USB (Optional) Windows family software and Mac OS
Network Surge Protection RJ45 I/O port available for network or FAX/Telephone line/Modem
Environmental Operating Temperature 0~40centi-degree
Operating Humidity 20~90% ( Non Condensing)
Weight Net weight (kg) 14 31.5 32 7 13.5 14
UPS Dimension L*W*H (mm) 400*145*220 460*192*348 460*192*348 400*145*220 460*192*348 460*192*348