| Model NO. | DX6K-DX20K/EX6KVA-EX20KVA |
| Type | On-line |
| Application | Communication |
| Standby Time | Standard Machine |
| Output Capacity | Medium Type |
| Brand | Zlpower |
| Voltage Range | 120-275V, 210-475V |
| Wave Form | Pure Sine Wave |
| Current Crest Ratio | 3:1 |
| Transfer Time | 0ms |
| Optional | Snmp, USB, etc. |
| Specification | CE, ISO, SGS |
| HS Code | 8504402000 |
| Phase | Single Phase |
| Protection | Short Circuit |
| Classification | Online |
| Standby UPS | Sine Wave Output UPS |
| Equipment Mode | Centralized Model |
| Capacity | 6kVA~20kVA |
| Input Phase | Single Phase with Ground |
| Power Factor | 0.8 |
| Connection | Terminal Block |
| Communication Software | RS232 |
| Trademark | ZLPOWER/OEM |
| Origin | Shenzhen, China |
| 0.8 UPS | STANDARD | DX6K | DX10K | DX6KL | DX10KL | DX3110KL | DX3115KL | DX3120KL | |
| 0.8 UPS | PROFESSIONAL | DX6K-P | DX10K-P | DX6KL-P | DX10KL-P | DX3110KL-P | DX3115KL-P | DX3120KL-P | |
| CAPACITY | VA/W | 6KVA/4.8KW | 10KVA/8KW | 6KVA/4.8KW | 10KVA/8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | |
| INPUT | Nominal Voltage | 220/230/240VAC | 380VAC | ||||||
| Voltage Range | 120-275VAC | 210-475VAC | |||||||
| Frequency Range | 46-64Hz: 50Hz, 60Hz auto sense | ||||||||
| Phase | Single phase with Ground | Three phase (4 Wires+Ground) | |||||||
| Power Factor | > =0.99 | > =0.95 | |||||||
| OUTPUT | Voltage | 220/230/240*(1± 1%)VACn; 1%)VAC; 1%)VAC | |||||||
| Frequency | 50/60Hz(Adjustable) 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1± 0.1%)n; 0.1%)n; 0.1%) 60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1± 0.1%)n; 0.1%)n; 0.1%) | ||||||||
| Wave Form | Pure Sine Wave | ||||||||
| Power Factor | 0.8 | ||||||||
| Harmonic Distortion | =< 2% THD (Linear Load), =< 6% THD (Non-Linear Load)ar Load) | ||||||||
| Overload Capacity | Normal when load < 105%; 105%-125% for 1min, 125%-150%for 30sec0sec | ||||||||
| Current Crest Ratio | 3: 1 | ||||||||
| Connections | Terminal block | ||||||||
| Efficiency | To AC Mode | 88% | 85% | ||||||
| To Battery Mode | up to 90% | ||||||||
| Battery | Type | Sealed free maintenance lead acid battery | |||||||
| Nominal DC voltage | Built in batteries 12v7.2ah*16pcs | 192VDC | 192VDC | ||||||
| Quantity | 16pcs | 16pcs | Depends on requested back-up time | Depends on requested back-up time | |||||
| Back-up Time (Full load) | ﹥ =7 minutesutes | ﹥ =5 minutesutes | Depends on the capacity of external battery bank | Depends on the capacity of external battery bank | |||||
| Recharge Time | 7 hours to 90% | Depends on the capacity of external battery bank | Depends on the capacity of external battery bank | ||||||
| Charge current(MAX) | 2.0A | 4.2A or 8A | 4.2A or 8A | ||||||
| Charge voltage | 220Vdc ± 1%usmn; 1%usmn; 1% | ||||||||
| Bypass | Automatic Transfer | On overload and UPS failure | |||||||
| Before UPS Power-on | Default ' ON' user adjustable to ' YES'e to " YES"; YES" | ||||||||
| Transfer Time | Zero | ||||||||
| Indicators | LED Display | UPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault codeault codeault code | |||||||
| Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault | ||||||||
| Acoustic noise | At 1 meter distance | < 55dB55dB | < 60dB60dB | ||||||
| Communications | Intelligent RS232 serial port | Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, Aix, True64, SGI IRIX, FreeBSD, HP-UX, and MAC | |||||||
| SNMP (Optional) | Power management from SNMP manager and web browser | ||||||||
| USB (Optional) | Windows family software and Mac OS | ||||||||
| Environmental | Operating Temperature | 0~40 | |||||||
| Operating Humidity | 20~90% ( Non Condensing) | ||||||||
| Weight | Net weight (kg) | 57 | 67.5 | 18 | 20 | 27 | 35 | 35 | |
| UPS Dimension | L*W*H (mm) | 500*248*616 | 500*248*616 | 500*240*460 | 500*240*460 | 500*248*616 | 500*248*616 | 500*248*616 | |
| There are two types: Standard type and Professional type, Professional type is with EPO, online maintenance and other functions. | |||||||||