1kVA~3kVA True Online UPS Power

1kVA~3kVA True Online UPS Power

5+
92-429 USD

add to cart
Model NO. EX1K-EX3KL
Type High Frequency Online UPS
Application Communication
Standby Time Standard Machine
Output Capacity Medium Type
Brand Zlpowr,OEM
Input Phase Single Phase with Ground
Output Power Factor 0.7/0.8
AC Mode Efficiency 85%
Current Crest Ratio 3:1
Operating Humudity 20-90% Non-Condensing
Specification CE, ISO9001
HS Code 8504402000
Phase Single Phase
Protection Cold Start, Surge Protection
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Centralized Model
Nominal Capacity 1kVA~3kVA
Wave Pure Sine Wave
Frequency 220,230,240V
Battery Mode Efficiency 83%
Operating Temperature 0-40centi-Degree
Trademark ZLPOWER
Origin Shenzhen, China
1KVA~3KVA true Online UPS Power
IP/OP: 110/115/120VAC 50/60Hz
IP/OP: 220/230/240VAC 50/60Hz
UPS APPLICATION:
Servers, Data-Center, Critical network devices, Sensitive
Electronic equipment, Telecom...
UPS KEY FEATURES:
High frequency tower UPS 1KVA-3KVA, with cold start and self test when start function, larger LCD display
True on-line double conversion technology with advanced microprocessor control
Wide input voltage range
Zero transfer time
Protection against all type of power problems
Self test while start of the UPS
Site wiring fault warning
On-battery power-on function
UPS power supplier Model EX1K EX1KL EX2K EX2KL EX3K EX3KL
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
Input Voltage (115~300) VAC
Frequency 46~54Hz/56~64Hz (Adjustable via LCD panel)
Output Voltage 220/230/240 (1± 1%) VAC (Adjustable via LCD panel)D panel)D panel)
Frequency 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode: 50Hz (1± 0.2%) 60Hz AC Mode: Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1± 0.2%)1± 0.2%); 0.2%)1± 0.2%)
Output Wave Form Sine Wave
Back-up Time Full Load ≥ 5′; 5′prime;; 5′ Depends on the capacity of the external battery bank ≥ 9′; 9′prime;; 9′ Depends on the capacity of the external battery bank ≥ 5′; 5′prime;; 5′ Depends on the capacity of the external battery bank
Half Load ≥ 14′ 14′prime; 14′ ≥ 21′ 21′prime; 21′ ≥ 15′ 15′prime; 15′
Battery Nominal DC Voltage 36VDC 96VDC
Transfer Time 0ms
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms
Communications RS-232+Intelligent Slot
Environment Temperature 0C~40C
Humidity 15%~90%
Dimensions (W*D*H)mm 145*400*220 192*460*340
Net Weight (Kg) 14 7 34 13.5 34.5 14