bargain
add to cart| Model NO. | RNF11 |
| Certification | ISO, CE, LVD |
| Rated Voltage | 48V |
| Parallel Operation | up to 3 Units |
| Environmental Protection Rating | Indoor(IP20) |
| Output Voltage | 230VAC |
| Transport Package | Carton/Wooden |
| Origin | Shenzhen, China |
| Condition | New |
| Application | Collector Controller, Water Heater Controller, Solar System Controller, Charger Controller, Lighting Controller, Wind Controller, Solar Working Station, Voltage Controller, Thermal Controller |
| Inbuilt Controller | Solar Charge Controller 40A/60A |
| Wave | Pure Sine Wave |
| Altitude | <=3000m |
| Trademark | Richwin/OEM/ODM/Neutral |
| Specification | Upon the model |
| HS Code | 8504403090 |

| MODEL | RNF11-2048 | RNF11-2048 Plus | RNF11-3048 | RNF11-4048 | |
| Default Battery System Voltage | 48VDC | ||||
| INVERTER OUTPUT | Rated capacity | 2500VA | 3750VA | 5000VA | |
| Rated output power | 2000W | 3000W | 4000W | ||
| Rated output voltage and frequency | 230Vac / 50Hz | ||||
| Rated output current | 8.7A | 13A | 17.4A | ||
| Output voltage precision | 230Vac±1%lusmn;1%lusmn;1% | ||||
| Output frequency precision | 50Hz±0.1%smn;0.1%smn;0.1% | ||||
| THD (Linear loads) | Off grid≤2%e;2%e;2% | ||||
| Grid discharge ≤3%e;3%e;3% | |||||
| Grid charge ≤3%e;3%e;3% | |||||
| Dynamic response speed(0←→100%;→100%;100%;→100%) | 20ms | ||||
| Power factor | Grid discharge 99.9% & Grid charge 99.9%99.9%99.9% | ||||
| Overload capability | 100%<load≤110%,30 minutes;tes;tes; 110%<load≤125%,1 minutes;tes;tes; 125%<load≤150%,30 seconds;nds;nds; load>150%,10 seconds; Short circuit,5 seconds | ||||
| Grid / Off grid change time | <10ms | ||||
| Output wave | sine wave | ||||
| Inverting efficiency 80% resistive loads | ≥92%;92%;92% | ≥93%;93%;93% | |||
| AC INPUT | AC input maximum current | 17.4A | 26A | 34.8A | |
| Acceptable input voltage range | Defaults 186Vac ~253Vac; Narrow 174Vac ~272Vac; Wide 95Vac ~272Vac | ||||
| Nominal frequency | 50Hz / 60Hz | ||||
| BATTERY | Rated input voltage | 48VDC | |||
| Allowed input DC voltage range | 40VDC ~ 62VDC | ||||
| Low voltage alarm | 42VDC | ||||
| High voltage alarm | 60VDC | ||||
| SOLAR CHARGER & AC CHARGER | PV Open Circuit Voltage | 145VDC | |||
| Max Solar Charging Current | 40A | 60A | 60A | ||
| Max AC Charging Current | 40A | 60A | 80A | ||
| DISPLAY & PROTECTION FUNCTIONCTIONCTION | LED indication | Systematic operation, indication of charge and discharge, indication of fault | |||
| LCD display | output voltage, output current, grid voltage, grid current, voltage of storage battery, load power, chart of capacity | ||||
| Protection Function | Input LV protection | ||||
| Input OV protection | |||||
| Output overload protection | |||||
| Output Short Circuit Protection | |||||
| MECHANICAL SPECIFICATIONS | Mounting | Wall mounted | |||
| W*H* D(mm)/Net Weight(kg) | 337*462*183mm/25kg | 337*462*183mm/29.5kg | 370*462*183mm/35kg | ||
| OTHER | Communication terminal | RS485 / CAN bus | |||
| Operation Temperature Range | -25ºC ~ +50ºC +50ºCrdm;C +50ºC | ||||
| Environmental Protection Rating | Indoor(IP20) | ||||
| Ambient humidity | 0 ~ 90% relative humidity(non-condensing) | ||||
| Altitude | ≤3000m000m000m | ||||
| Model | Load(W) | Backup Time@48V 100Ah(min) | Backup Time@48V 200Ah(min) |
| 2KW | 200 | 1270 | 2541 |
| 1000 | 208 | 488 | |
| 2000 | 82 | 203 | |
| 3KW | 300 | 847 | 1694 |
| 1500 | 123 | 315 | |
| 3000 | 50 | 123 | |
| 4KW | 400 | 614 | 1281 |
| 2000 | 89 | 205 | |
| 4000 | 38 | 89 |