bargain
add to cart| Model NO. | EA900II 2KVA long back up model or standard model |
| Type | On-line |
| Application | Communication |
| Standby Time | Long-acting Machine |
| Output Capacity | Medium Type |
| Brand | East |
| Specification | CE, LVD, EMC |
| HS Code | 850440 |
| Phase | Single Phase |
| Protection | Overvoltage |
| Classification | Online High Frequency UPS |
| Standby UPS | Sine Wave Output UPS |
| Equipment Mode | Standard Type or Long Back up Type |
| Trademark | EAST, OEM |
| Origin | Dongguan China |
| MODEL | EA901II | EA902II | EA903II | EA906II | EA9010II | ||||||
| Capacity | 1KVA/900W | 2KVA/1800W | 3KVA/2700W | 6KVA/5400W | 10KVA/9000W | ||||||
| INPUT | |||||||||||
| Rated Voltage | 208V/220V/230V/240VAC | ||||||||||
| VoltageRange | Half load (115-295)±5VACusmn;5VACsmn;5VAC Full load (145-295)±5VACusmn;5VACsmn;5VAC | Half load (115-295)±5VACusmn;5VACsmn;5VAC Full load (165-295)±5VACusmn;5VACsmn;5VAC | |||||||||
| Frequency | 45-55Hz±0.5%or 55-65Hz±0.5% (Auto Sensing)% (Auto Sensing) (Auto Sensing) | 40-70Hz±0.5% (Auto Sensing) Sensing)Sensing) | |||||||||
| Power Factor | ≥0.98;0.980.98 | ≥0.99;0.990.99 | |||||||||
| BypassVoltage Range | Rated output voltage-34V ~ Rated output voltage+32V | 160V ~ Rated output voltage+32V | |||||||||
| OUTPUT | |||||||||||
| Voltage | 208V/220V/230V/240VAC Setting available via LCD | ||||||||||
| Voltage Regulation | ±1%plusmn;1%lusmn;1% | ||||||||||
| Frequency | Synchronized with utility on AC mode;50/60±0.2Hz on battery modetery modeery mode | ||||||||||
| Waveform | Pure sine wave | ||||||||||
| Crest Factor | 3:1 | ||||||||||
| Harmonic Distortion | ≤3%(Linear load);≤5%(Non-linear load)ar load)r load) | ≤2%(Linear load);≤5%(Non-linear load)ar load)r load) | |||||||||
| Transfer Time | AC mode to battery mode :0ms Inverter model to bypass mode:4ms(Typical) | AC mode to battery mode :0ms Inverter model to bypass mode:0ms | |||||||||
| Overload Capability | 105%-150%:Transfer to bypass after 30s; ﹥150%: Transfer to bypass after 300ms300ms | 105%-125%:Transfer to bypass after 3mins; 125%-150%: Transfer to bypass after 30s; ﹥150%: Transfer to bypass after 100ms100ms | |||||||||
| EFFICIENCY | |||||||||||
| AC Mode | ≥90%e;90%;90% | ≥92%e;92%;92% | |||||||||
| BatteryMode | ≥87%e;87%;87% | ≥91%e;91%;91% | |||||||||
| ECO Mode | ≥98%e;98%;98% | ≥98%e;98%;98% | |||||||||
| BATTERY | |||||||||||
| DC Voltage | 24V | 36V | 48V | 72V | 72V | 96V | 192V | ||||
| Inbuilt Batteryof Standard Model | 2*9Ah | 3*7Ah | 4*9Ah | 6*7Ah | 6*9Ah | 8*7Ah | 16*7Ah | 16*9Ah | |||
| Charge Current | Standard Model | 1A | |||||||||
| Long Time Model | 6A | 1A/3A/5A/8A | |||||||||
| Typical Recharge Time | 8 hours recover to 90% capacity | ||||||||||
| ALARM | |||||||||||
| Utility Failure | Beep/4s | ||||||||||
| BatteryLow | Beep/1s | ||||||||||
| Overload | Beep Twice/1s | ||||||||||
| UPS Fault | Long Beep | ||||||||||
| ENVIRONMENT | |||||||||||
| Humidity | 20~90% RH @ 0~40°C(non-condensing)nsing)sing) | ||||||||||
| Noise Level | ≤50dB (1m) (1m)(1m) | ≤55dB (1m) (1m)(1m) | |||||||||
| MANAGEMENT | |||||||||||
| Standard RS-232 ,Optional USB | Supports Windows 98/2000/2003/XP/Vista/2008/7/8 | ||||||||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||||||||
| PHYSICAL | |||||||||||
| Dimension(mm) W*D*H | 144*357*215 | 144*410*215 | 190*452*341 | 190*470*341 | 190*452*341 | 190*470*341 | 262*514*455(H) 262*514*735(S) | ||||
| Packing Dimension(mm) W*D*H | 230*445*315 | 230*492*315 | 320*550*462 | 360*650*540(H) 360*650*795(S) | |||||||
| Net Weight(kg) | 6.0(H)10.0(S) | 6.5(H)13.0(S) | 12.0(H)20.0(S) | 13.0(H)25.0(S) | 12.0(H) 24.0(S) | 13.0(H) 29.0(S) | 26.0(H) 67.0(S) | ||||
| Gross Weight(kg) | 7.0(H)11.0(S) | 7.7(H)14.5(S) | 13.3(H)21.5(S) | 14.3(H)26.5(S) | 13.3(H)25.5(S) | 14.3(H) 30.5(S) | 28.0(H) 78.0(S) | ||||