Online High Frequency UPS Ea900 (1-10kVA)

Online High Frequency UPS Ea900 (1-10kVA)

bargain

add to cart
Model NO. EA900N
Type On-line
Application Communication
Output Capacity Medium Type
Trademark EAST, OEM
Origin China
Phase Single Phase
Protection Overcurrent
Classification Lighting/Power
Brand East
Specification EMC50091, 9254
HS Code 850440
True on-line technology provides all power protection
High frequency and double conversion on-line technology
Wide input voltage range
Advanced PFC technology
Pure sine wave output with less than 3% THD
Automatic diagnostics & battery checkcheckcheck
Self-testing when UPS startup
Advanced battery management(ABM)
Cold start function(DC power on)
Automatic battery charging in UPS off mode
Lightning and surge protection (surge energy rating 1050 Joules)
Short circuit and overload protection
Fan speed auto control when loads varies
Optional extension battery pack
EMI/RFI noise filter
Smart RS232 communication with monitoring software
Schedule shutdown & restartstartstart
Large LCD display
Online Model EA901N EA902N EA903N EA906N EA910N
Capacity(linear Load)
1KVA/700W
2KVA/1400W 3KVA/2100W 6KVA/4200W 10KVA/7KW
Input Voltage Range Half Load 120-300VAC
Full Load 165V-276VAC
176V-290VAC
Frequency Range 45.5Hz~54Hz
Output Voltage 220V/230V/240V±3%plusmn;3%lusmn;3%
Output Frequency 50/60Hz±0.5Hzsmn;0.5Hzmn;0.5Hz
Output Voltage Tolerance <±5%(100% Load or without Load)ithout Load)
Distortion <3%(Linear Load); <5%(Non-linear load)ar load)
Output Waveform True Sine Wave
Overload Capability 110%~150%: transfer to Bypass after
1Mins, above 150%: 200MS
105%~130%, 10Mins; ﹥130%:1Min.1Min.
Battery Voltage 36VDC 96VDC 240VDC
ChargeVoltage 40.5±1Vplusmn;1Vlusmn;1V 110±1Vplusmn;1Vlusmn;1V 274.5±1Vplusmn;1Vlusmn;1V
Battery Type Sealed Maintenance-FreeLead-Acid
Batteries Q'TY 12V×3Pcsmes;3Pcses;3Pcs 12V×8Pcsmes;8Pcses;8Pcs 12V×20Pcses;20Pcss;20Pcs
Standard Backup Time(Full Load/Half Load) 5/12Mins 7/16Mins 5/13Mins 6/15Mins 8/20Mins
Crest Factor 3:1
Noise( 1m ) <45db;45db <50db;50db <55db;55db
LCD and LED Utility, Inverter, Bypass, Battery, Load, Battery Mode, Frequency,
UPS Fault Indicator
Transfer Time of AC to DC Zero
Battery Low Voltage 31±2Vplusmn;2Vlusmn;2V 83±2Vplusmn;2Vlusmn;2V 200±2Vplusmn;2Vlusmn;2V 210±2Vplusmn;2Vlusmn;2V
Charge Time Charging up to 90% , ≤8HoursHoursours
Audible Alarm-Battery Discharge Utility Failure, Beep/4s ; Battery Low, Beep/1s
EMC 50091 , 9254
UPS Abnormal Continuous Beep and Red LED on
Output Short Circuit Shutdown
Outlets 2pcs 3pcs Terminals
Communication Interface RS232/SNMP ( optional )
Ambient Temperature 0 ~ 40
Humidity 10%~90%
Net Weight(Kg) UPS 13.5 12.5 29.5 30.50
Battery N/A 26.0 50.0 60.0
Dimension(W×D×H)mms;D×H)mm;H)mms;D×H)mm UPS 482×445×90s;445×90es;90s;445×90 482×448×90s;448×90es;90s;448×90 535×653×283;653×283s;283;653×283
Battery
Packing Measure (W×D×H)mms;D×H)mm;H)mms;D×H)mm UPS 515×515×180;515×180s;180;515×180 515×548×180;548×180s;180;548×180 5357×653×283;653×283s;283;653×283
Battery
20FT 600 PCs 300PCs 100PCs