CE Certificate Home Use Easy Operate Sinewave Inverter

CE Certificate Home Use Easy Operate Sinewave Inverter

1+
189.5 USD
10+
279.6 USD

add to cart
Model NO. EP3000
Type DC/AC Inverters
Output Power >1000W
Certification CE, ISO9001
Weight 18-60kg
Power 1kw-6kw
Input Votlage 155-265VAC for 230VAC, 90-120VAC for 120VAC
Charge Current 70A Max
Remote Control Option
Trademark MUST
Origin Shenzhen, China
Phase Single
Power Source Electric Power
Nature of Wave String Sine Wave Inverter
Brand Must/OEM
Colour Black ,White
DC 12V/24V/48V
Input Frequency 40-80Hz
Charge Currante Adjustable Yes
RS232 Option
Specification CE, ISO,
HS Code 8504409990
CE Certificate Home Use Easy Operate Sinewave Inverter
Pure sine wave inverter solar inverter
Durable construction for long life under extreme environmental conditions
Low idle current (less than 1 watt) conserves energy when no loads are present
Soft start capability for starting heavy loads;
Built-in starting control circuits for two- and three-wire generator starting systems;
Simplified controls with a snap-on cover that protects settings from being accidentally changed;
Better thermal performance allows full output power to 50° C (122° F) without de-rating;e-rating;e-rating;
High surge capacity starts more difficult loads and handles overload conditions reliably;
Durable powder coated, corrosion resistant steel chassis.
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging, plus incorporates a robust ON/OFF switch and status indicators;
70-AMP automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance;
New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery charging algorithm, reduces electricity draw and generator run-time.
MODEL
(EP3000)
HV Model
1012E 1024E 2012E 2024E 3024E 4048E 5048E 6048E
Line Mode Specifications:
Input Voltage Waveform Sinusoidal (utility or generator)
Nominal Input Voltage 230Vac(120VAC selectable)
Low Line Disconnect 184Vac±4%lusmn;4%lusmn;4%
Low Line Re-connect 194Vac ±4%lusmn;4%lusmn;4%
High Line Disconnect 265Vac±4%lusmn;4%lusmn;4%
High Line Re-connect 255Vac±4%lusmn;4%lusmn;4%
Max AC Input Voltage 270Vrms
Nominal Input Frequency 50Hz/ 60Hz (Auto detection)
Low Line Frequency Re-connect 58+0.3Hz for 60Hz;48+0.3Hz for 50Hz;
Low Line Frequency Disconnect 57+0.3Hz for 60Hz;47+0.3Hz for 50Hz;
High Line Frequency Re-connect 64+0.3Hz for 60Hz;54+0.3Hz for 50Hz;
High Line Frequency Disconnect
65+0.3Hz for 60Hz;55+0.3Hz for 50Hz;
Output Voltage Waveform As same as Input Waveform
Over-Load Protection(SMPSload) Circuit breaker
Output Short Circuit Protection Circuit breaker
Efficiency (Line Mode) >95%
Transfer Switch Rating 30A
Transfer Time (Ac to Dc) 10ms (typical)
Transfer Time (Dc to Ac) 10ms (typical)
Pass through without Battery Yes
Max Bypass Overload Current 30A
Invert Mode Specifications:
Output Voltage Waveform Sine wave
Rated Output Power (VA) 1000 2000 3000 4000 5000 6000
Rated Output Power (W) 1000 2000 3000 4000 5000 6000
Power Factor 0~1.0
Nominal Output Voltage (V) 230Vac
Nominal Output Frequency (Hz) 50Hz ± 0.3Hzn; 0.3Hzn; 0.3Hz
Auto tracking Main Frequency(Hz) Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz
Output Voltage Regulation ±10% rms;10% rms;10% rms
Nominal Efficiency >80%

Over-Load Protection
(SMPS load)
(110% 150% ±10%: Fault (shutdown output) after 20s;ter 20s;ter 20s;
Surge rating (10s) 3000VA 6000VA 9000VA 12000VA 15000 VA 18000VA
Capable of starting electric motor 1 HP 1 HP 2 HP 3 HP
Output Short Circuit Protection Current limit (Fault after 10s)
Inverter overload Breaker Size 30A 30A 30A 35A 50A
Nominal DC Input Voltage 12V 24V 12V 24V 24V 48V 48V
Min DC start voltage 10V/20V/40V
Low Battery Alarm 10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery0.6Vdc for 48V battery0.6Vdc for 48V battery
Low DC input Shut-down 10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery0.6Vdc for 48V battery0.6Vdc for 48V battery
High DC input Alarm & FaultFaultFault 16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery0.6Vdc for 48V battery0.6Vdc for 48V battery
High DC input Recovery 15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery0.6Vdc for 48V battery0.6Vdc for 48V battery
Power saver Load ≤25W (Enabled on 'P/S auto' setting of Remote control)emote control)rol)
Charge Mode Specifications:
Nominal Input Voltage 230Vac
Input Voltage Range 196~243Vac
Nominal Output Voltage According to the battery type
Nominal Charge Current 35A 35A 65A 35A 45A 35A 40A 50A
Charge Current Regulation ± 5Adcmn; 5Adcmn; 5Adc
Battery initial voltage 0 –15.7 Vdc (can operate with 0V battery)attery)attery)
Charger Short Circuit Protection Circuit breaker
Over Charge Protection Bat. V ≥15.7Vdc/31.4Vdc,beeps 0.5s every 1s & fault after 60sfter 60sfter 60s
General Specifications
Safety Certification CE(EN62040-1)
EMC Classification EN62040-2,C2
Operating Temperature Range 0°C to 40°C 40°Ceg;C 40°C
Storage temperature 15°C below zero to 60°C 60°Ceg;C 60°C
Operation humidity 5% to 95%
Audible Noise 60dB max
Cooling Forced air, variable speed fan
Size 1012E/1024E2012/2024E/2048E:381mm*217mm*179mm
3012/3024E/3048E/5024E/5048E/6024E/6048E:461 mm*217mm*179mm