Pure Sine Wave 500va-1500va Power Inverter

Pure Sine Wave 500va-1500va Power Inverter

bargain

add to cart
Model NO. EP2000 Series
Type DC/AC Inverters
Charge Current Max 20AMP
Capacity 300-1000W
Power Source Electric Power
Transport Package Carton
Origin China
Output Power 501 - 1000W
AVR Function Yes
Frequency Low Frequency
Phase Single
Trademark MUST
Specification ISO9001, CE
HS Code 8504403090

Main features:
rack/tower type
LCD/LED display
built in charger
with AVR function
with transformer inside
RS232 port optional
Special charging system design for better protection of battery life.
Short circuit, overload, over voltage and low battery protection.
Compatible with generators and suitable for harsh environment.
With standard on-line structure (three ports)and can be used as UPS. Specification
MODEL EP20-300W EP20-600W EP20-800W EP20-1KW
Default Battery System Voltage 12VDC 12VDC 12VDC/24VDC 12VDC/24VDC
INVERTER OUTPUT Reted Power 300W 600W 800W 1000W
Waveform Pure sine wave
Nominal Output Voltage RMS 100V/110V/120VAC 220V/230V/240VAC(±10% RMS)10% RMS)10% RMS)
Output Frequency 5OHz/60Hz±0.3 Hzn;0.3 Hzn;0.3 Hz
Inverter Efficiency(Peak) >80%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time Typical 2~6ms ,10ms max
AC INPUT Voltage 220VAC
Selectable Voltage Range 96~132VAC 145~275VAC(For Personal Computers)
Frequency Range 50Hz/60Hz (Auto sensing 44~68Hz)
BATTERY Nominal Input Voltage 12VDC 12VDC/24VDC 12VDC/24VDC 12VDC/24VDC
Minimum Start Voltage 10.5VDC /21.0VDC
Low Battery Alarm 10.5±0.3V /21.0VDC±0.6VVDC±0.6Vmn;0.6VVDC±0.6V
Low Battery Cutoff 10.0VDC±0.3V /20.0VDC±0.6VVDC±0.6Vmn;0.6VVDC±0.6V
High Voltage Alarm 15.5VDC±0.3V /31.0VDC±0.6VVDC±0.6Vmn;0.6VVDC±0.6V
High Battery Voltage Recover 15.0VDC±0.3V /30.0VDC±0.6VVDC±0.6Vmn;0.6VVDC±0.6V
CHARGER Charger Voltage 14.0V±0.2/28.0V±0.48.0V±0.4smn;0.48.0V±0.4
Overcharge Protection S.D. 15.5VDC/31.0VDC
Maximum Charge Current 15A~25A
BYPASS & PROTECTIONCTIONCTION Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) IPS automatically shutdown if overload exceeds 120% ofnormal value for 30 seconds IPS automatically resume work if overload comes back to rated load
Output Short Circuit Protection FUSE
Bypass Breaker Rating 10A
Max Bypass Current 10Amp
MECHANICAL SPECIFICATIONS Dimensions (W*H*D) 265*120*295mm
Net Weight (kg) 7.0kg 10.5kg 12kg 12.5kg
Shipping Dimensions(W*H*D) 316*185*377mm
Shipping Weight (kg) 7.5kg 11kg 12.5kg 13kg
OTHER Operation Temperature Range 0°C to 40°C 40°Ceg;C 40°C
Audible Noise 60dB MAX
Display LED or LCD Optional
Standard Warranty 1 year