LW Inverter Series 1000W-4000W 110V/120Vac output
Application: All kinds of home applicance,office equipment, solar power system,and other
equipments which use single phase power
Key Features:
♦Pure sine wave output, available for sensitive loadve loadve load
♦3-step progressive charging,7 battery type selectorelectorelector
♦35A/50A/70A/90A (According to the inverter model) model) model)
♦Accept generator's energy output output output
♦Automatically transfer between battery and line modese modese modes
♦Microprocessor control guarantees high reliabilityabilityability
♦Bypass without battery connectednnectednnected
♦Remote control functionunctionunction
♦Protection against Over load, over temperature, over charging, low batterybatterybattery
Reverse connection (optional by hard connector)
Warranty: 24months
Delivery time: 3-15days
Specificaiton:
| Model Parameters | LW1000 | LW2000 | LW3000 | LW4000 |
| AC Input | Nominal Power | 1000W | 2000W | 3000W | 4000W |
| Voltage | 120VAC/230VAC |
| Acceptable Voltage | 194-243VAC/164-243VAC(wide mode) |
| Line low Transfer | 85V±4%/184(154 wide mode±4% )ode±4% )mn;4% )ode±4% ) |
| Line low Return | 95V±4%/194(164 wide mode±4% )ode±4% )mn;4% )ode±4% ) |
| Line high Transfer | 135V±4%/253±4%%/253±4%usmn;4%%/253±4% |
| Line high Return | 127V±4%/243±4%%/243±4%usmn;4%%/243±4% |
| Frequency | 50Hz or 60Hz |
| Line low Transfer | 47Hz for 50Hz, 57Hz for 60 Hz |
| Line high Transfer | 55Hz for 50Hz, 65Hz for 60 Hz |
| Out Input | Phase &waveformeformeform | Pure Sine Wave(bypass mode sync to input) |
| Voltage | 100/110/120/130VAC, 208/220/230/240VAC (bypass mode sync to input) |
| Voltage Regulation | ±10%rms(bypass mode sync to input)o input)o input) |
| Frequency | 50Hz±0.3Hz(bypass mode sync to input)o input)o input) |
| Peak Power | 3 times of rating power |
| Short Circuit Protection | Yes, shutdown after 10ms |
| Power Factor | 0.9-1.0 |
| Solar Charger | Battery Voltage | 12V/24V/48V | 24V/48V |
| Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V |
| Low Battery Alarm | 10.5V for 12V, 21V for 24V, 42V for 48V |
| Low Battery Transfer | 10V for 12V, 20V for 24V, 40V for 48V |
| High Voltage Alarm | 16V for 12V, 32V for 24V,64V for 48V |
| Max Charging Current | 35A/70A |
| Over charge Voltage | 15.7V for 12V,31.4V for 24V, 62.8V for 48V |
| Transfer Efficiency | Line Mode | >95% |
| Battery Mode | >88% |
| Power saver | Available when the load is less than 25 Watts |
| Indicators | Switch selector | Saving Mode is on/off when push the switch forwards/backwards ,Keeping it horizontal is turning the inverter off. |
| Audible Alarm | Sounding when the heatsink's tem is over 105ºC and shutdown after 30 seconds.conds.conds. |
| Protections | low battery/ over charging /over temp/over load |
| Communications | RS-232/USB(custom-made) |
| Enviromental | Operating Environment | 0-40ºC,0-90%ºC RH(non-condensing)condensing)condensing) |
| Audible Noise | <60dB60dB |
| Net Weight (KG) | 14.5 | 19 | 24.5 | 34.5 |
| Dimension(LxWxH) | 480×225×190mm5×190mm;190mm5×190mm | 660×225×200mm5×200mm;200mm5×200mm |