bargain
add to cart| Model NO. | LW500W,750W,LW1K,2KW,3KW,4KW,5KW,6KW,7KW,8KW |
| Output Power | 501 - 1000W |
| Power Source | Solar Power |
| Output Voltage | 110V, 120V, 220V, 230V, 240V AC +/- 5% |
| Max Bypass Current | 30AMPS |
| Bypass Overload Current | 35AMP Alarm |
| Charge Battery Type | Gel Battery, Deep Cycle Battery, VRLA Battery |
| Specification | CE |
| HS Code | 8504403090 |
| Phase | Single |
| Type | DC/AC Inverters |
| Input Voltage | 12V, 24V, 48V DC |
| Surge Rating | Three Times as Continuous Watts |
| Bypass | Bypass Without Battery Connected |
| Mminimum Start Voltage | 10V |
| Trademark | ZLPOWER |
| Origin | Shenzhen, China |



| MODEL | LW-500 | LW-750 | LW-1000 | |
| Nominal Power | 500W | 750W | 1000W | |
| AC Input | ||||
| Phase & waveform | Single phase & Pure Sine Wave Wave Wave | |||
| Voltage | 110/120/130VAC or 220/230/240VAC | |||
| Acceptable Voltage | 95-126VAC or 194-253VAC±4%plusmn;4%lusmn;4% | |||
| Low Line Disconnect | 85VAC±4% or 184VAC±4%84VAC±4%usmn;4%84VAC±4% | |||
| Low Line Re-connect | 95VAC±4% or 194VAC±4%94VAC±4%usmn;4%94VAC±4% | |||
| High Line Disconnect | 136VAC±4% or 263VAC±4%63VAC±4%usmn;4%63VAC±4% | |||
| High Line Re-connect | 126VAC±4% or 253VAC±4%53VAC±4%usmn;4%53VAC±4% | |||
| Frequency | 50Hz:41-54Hz 60Hz:51-64Hz | |||
| AC Output | ||||
| Phase & waveformeformeform | Single phase & Pure Sine Wave (bypass mode sync to input)nput)nput) | |||
| Voltage | 110/120/130VAC or 220/230/240VAC±10%rms (bypass mode sync to input)o input)o input) | |||
| Frequency | 50Hz±0.3Hz 60Hz±0.3Hz (bypass mode sync to input) sync to input) sync to input) | |||
| Peak Power | 3 times of rating power | |||
| Short Circuit Protection | Yes, shutdown after 10ms | |||
| Power Factor | 0.9-1.0 | |||
| DC Input | ||||
| Battery Voltage | 12VDC or 24VDC | |||
| Minimum Start Voltage | 10VDC or 20VDC | |||
| Low Battery Alarm | 10.5±0.3vdc or 21±0.6vdc1±0.6vdc;0.6vdc1±0.6vdc | |||
| Low DC input Shut-down | 10±0.3vdc or 20±0.6vdc0±0.6vdc;0.6vdc0±0.6vdc | |||
| High DC input Alarm & FaultFaultFault | 16±0.3vdc or 32±0.6vdc2±0.6vdc;0.6vdc2±0.6vdc | |||
| High DC input Recovery | 15.5±0.3vdc or 31±0.6vdc1±0.6vdc;0.6vdc1±0.6vdc | |||
| MAX Charger Current | 20A/35A (According to the Inverter model) | |||
| System parameter | ||||
| Battery Mode Efficiency | >85% | |||
| Line Mode Efficiency | >96% | |||
| power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control)emote control) | |||
| Audible Alarm | Sounding when the heat sink's tem is over 100 degree and shutdown after 30 seconds. | |||
| Over Load Protection | 110% | |||
| Protections | low battery,over charging,over temp,over load | |||
| Communications | RS-232/USB/SNMP(custom-made) | |||
| Operating Environment | 0-40 degree,0-90%RH(non-condensing) | |||
| Audible Noise | <60dB60dB | |||
| Net Weight(KG) | 8.5kg | 11kg | 14.5kg | |
| Dimension L X W X H | 380 X182 X160mm | |||