add to cart| Model NO. | RCM19F |
| Certification | CE |
| Rated Voltage | 12VDC/24VDC/36VDC/48VDC(Auto Detection) |
| Radiating Mode | Fan Cooling |
| Transport Package | Carton |
| Origin | Shenzhen, China |
| Condition | New |
| Application | Collector Controller, Water Heater Controller, Solar System Controller, Charger Controller, Lighting Controller, Wind Controller, Solar Working Station, Voltage Controller, Thermal Controller |
| Charge Current | 45 /60/80 AMPS Continuous |
| Trademark | Richwin/OEM/ODM/Neutral |
| Specification | 167.6*257.1*82.9mm |
| HS Code | 8537109021 |


| Model | RCM19F-45A | RCM19F-60A | RCM19F-80A | |
| Default Battery System Voltage | 12V/24V/36V/48VDC (Auto detection) | |||
| CONTROLLER INPUT | PV Open Circuit Voltage | 100VDC@12V/ 145VDC @24V/ 145VDC @36V/ 145VDC @48V | ||
| PV Array MPPT Voltage Range | 16VDC~100VDC / 32VDC~130VDC / 48VDC~130VDC / 64VDC~130VDC | |||
| Max PV Input Power(12V) | 600W | 800W | 1050W | |
| Max PV Input Power(24V) | 1200W | 1600W | 2100W | |
| Max PV Input Power(36V) | 1800W | 2400W | 3150W | |
| Max PV Input Power(48V) | 2400W | 3200W | 4200W | |
| BATTERY | Absorption Voltage | 12.5VDC/25.0VDC/37.5VDC/50.0VDC | ||
| Refloat Voltage | 13.7VDC/27.4VDC/41.1VDC/54.8VDC | |||
| Float Voltage | 14.3VDC/28.6VDC/42.9VDC/57.2VDC | |||
| Low Voltage Protection Point | 10VDC/20VDC/30VDC/40VDC | |||
| Temperature Compensation coefficient | -3mv/°C /cell (25°C vef)eg;C vef)eg;C vef) | |||
| BATTERY | Peak Conversion efficiency | 98% (MPPT Efficiency 99%) | ||
| Max Charging Current | 45 amps continuous @ 40°C ambientbientbient | 60 amps continuous @ 40°C ambientbientbient | 80 amps continuous @ 40°C ambientbientbient | |
| GENERAL SPECIFICATION | Radiating mode | Fan cooling | ||
| DISPLAY & PROTECTIONCTIONCTION | LED indication | Systematic operation, LV indication, LV protection, over charge protection, short circuit protection | ||
| LCD display | Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current | |||
| Alarm Protections | PV array short circuit, PV reverse polarity | |||
| Battery reverse polarity, Over charging protection | ||||
| Output short circuit protection | ||||
| Low voltage protection for storage battery | ||||
| MECHANICAL SPECIFICATIONS | Mounting | Wall mount | ||
| W*H* D(mm)/Net Weight(kg) | 167.6*257.1*82.9mm/3kg | |||
| OTHER | Environmental Rating | Indoor | ||
| Operation Temperature Range | -25~55°Cdeg;Cdeg;C | |||
| Ambient humidity | 0~90% relative humidity(non-condensing) | |||
| Altitude | ≤3000m000m000m | |||
| Loading(20GP/40GP/40HQ) | 3000pcs / 6000pcs / 7200pcs | |||