Home Used 1kVA 2kVA Modified Sine Wave Small Size Inverter for Karachi 10A/20A battery charger buit-in
High reliability with CPU control.
Inner-equipped protection of over-load, short-circuit, over-voltage, low-voltage over-heating
Self-diagnosis function, capable of detecting status at inverter and battery in the Inverter.
Extra long standby time. And additional battery connections possible for longer power supply time according to customer's requirements.
| MODEL | P1000C | P2000C |
| OUTPUT |
| Power Levels crated at nominal inputs | 1000VA:600W | 2000VA1200W |
| Output Voltage | 230V | 230V |
| Phase | Single |
| Voltage Waveform | Modified Sine Wave |
| Power Factor | 0.6 |
| Output Frequency(Synchronized to Mains) | Auto Select for 50/60Hz |
| Regulation (Nominal) | 10%-18% |
| Regulation(Battery mode) | ±0.1HZmn;0.1HZmn;0.1HZ |
| Transfer time | 10ms Typical |
| INPUT |
| Nominal Voltage | 220V/230V/240V Selectable | 220V/230V/240V Selectable |
| Phase | Single |
| Voltage range | 180-275VAC ( Narrow Range ) |
| 80-275VAC (Wide Range) |
| BATTERY |
| Charger Current | 1000VA/600W12VDC/:10Amp/20Amp + / - 1Amp; 2000VA/1200W24VDC:10Amp/20Amp + / - 1Amp |
| Floating Voltage | 600W:13.7V + / - 0.4V; 1200W:27.4V + / - 0.4V |
| Protection | overcharge protection:1000VA/600W:15V +/- 0.6V charger stops and fault |
| overcharge protection: 2000VA/1200W: 30V +/- 0.6V charger stops and fault |
| other protection: discharge, overload |
| EFFICIENCY |
| AC to AC | 95% "> >95% |
| DC to AC | >80% |
| INDICATOR |
| AC Mode | Green LED/LCD lighting |
| Battery Mode | Yellow LED/LCD lighting |
| Battery Charging Mode | Green LED /LCDflashing every 2 seconds |
| Overload | Red LED/LCD flashing every 0.5 second |
| Fault | Red LED/LCD lighting |
| AUDIBLE ALARM |
| Low Battery at Battery Mode | Sounding every 2 seconds |
| Overload | Sounding every 0.5 second |
| Fault | Continously sounding |
| Protection |
| Full Rrotection | Deep Discharge, Overcharge, and Overload protection |
| ENVIRONMENTAL AND SAFETY |
| Operating Temperature | Up to 1500 meters:0 °Cto 40°C (32°F to 104°F)g;F to 104°F)g;F)g;F to 104°F) |
| Transit/storage Temp. | 15°C below zero to 50°C (5°F to 131°F)g;F to 131°F)g;F)g;F to 131°F) |
| Relative Humidity | 0 - 90% non condensing |
| Quality control system | ISO 9001:2000, ISO 14002-2004 |
| PHYSICAL |
| Appearance | Size(mm)L x W x H | 224*255*80 |
| Net Weight(Kg) | 600W:2.3kgs; 1200W :2.3kgs |
| Carton BOX(mm)L x W x H | 400*347*596(6pcs) |
| Gross Weight(Kg) | 1000VA /600W :16.8kgs ; 2000VA / 1200W :17.2kgs |