LCD Display Modified Sine Wave UPS Inverter 1000va 2400va

LCD Display Modified Sine Wave UPS Inverter 1000va 2400va

56 USD

add to cart
Model NO. EP1100 series
PCB Board Double Layers
Wide Input Voltage Range 90-280VAC
DC Battery 12V or 24V
Transport Package Gift Box + Carton Box
Origin China
Charge Current 10A/20A Adjutable
Narrow Input Voltage Range 170-280VAC
Wave Modified Sine Wave
Trademark MUST / OEM service for client
Specification SGS
HS Code 8504403090
Application:
- High quality and availability of energy adapted to suit specific critical needs, covering a vast range of applications.
-Applied to TV, stereos, laptop and desktop computers and other home appliance.
-It will automatically transfer to inverter and provide power when AC supply is interrupted unexpectedly.
MODEL EP11-1200 EP11-2400
Default Battery System Voltage 12VDC 24VDC
INVERTER
OUTPUT
Reted Power 1200VA/720W 2400VA/1440W
Waveform Modifide Sine-wave
Nominal Output Voltage RMS 230V
Output Voltage Regulation +10/-18%
Output Frequency 5OHz/60Hz±0.5 Hzn;0.5 Hzn;0.5 Hz
Inverter Efficiency(Peak) >80%
Line Mode Efficiency >95%
Power Factor 0.72
Typical Transfer Time Typical 15~20ms 40ms max
AC
INPUT
Voltage 230VAC
Selectable Voltage Range Narrow 170~280VAC
Wide 90~280VAC
Frequency Range 50Hz/60Hz (Auto sensing)
BATTERY Nominal Input Voltage 12VDC 24VDC
Minimum Start Voltage 10.5VDC
21.0VDC
Low Battery Alarm 10.5VDC±0.3Vsmn;0.3Vsmn;0.3V
21.0VDC±0.3Vsmn;0.3Vsmn;0.3V
Low Battery Cutoff 10.0VDC±0.3Vsmn;0.3Vsmn;0.3V
20.0VDC±0.3Vsmn;0.3Vsmn;0.3V
High Voltage Alarm 16.0VDC±0.3Vsmn;0.3Vsmn;0.3V
32.0VDC±0.3Vsmn;0.3Vsmn;0.3V
High Battery Voltage Recover 15.0VDC±0.3Vsmn;0.3Vsmn;0.3V 30.0VDC±0.3Vsmn;0.3Vsmn;0.3V
CHARGER Charger Voltage (Vbat<12.5V).5V) 14.4VDC±0.4Vsmn;0.4Vsmn;0.4V 28.8VDC±0.4Vsmn;0.4Vsmn;0.4V
Charger Voltage (Vbat﹥12.5V).5V) 13.7VDC±0.2Vsmn;0.2Vsmn;0.2V 27.4VDC±0.2Vsmn;0.2Vsmn;0.2V
Charging Current 10A 10A±2Alusmn;2Alusmn;2A
Charging Current 20A 20A±2Alusmn;2Alusmn;2A
Overcharge Protection S.D. 16VDC ±0.4Asmn;0.4Asmn;0.4A
32VDC ±0.8Asmn;0.8Asmn;0.8A
BYPASS
&
PROTECTION
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) FUSE
Output Short Circuit Protection FUSE
Bypass Breaker Rating 10A
Max Bypass Current 10Amp
MECHANICAL
SPECIFICATIONS
Dimensions (W*H*D) 246*253*87mm
Net Weight (kg) 2.3 2.5
Shipping Dimensions(W*H*D) 320*332*127mm
Shipping Weight (kg) 2.9 3.1
OTHER Operation Temperature Range 0°C to 40°C 40°Ceg;C 40°C
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 1 year