Intelligent Low Frequency Online UPS 10KVA-200KVA, Three Phase UPS

Intelligent Low Frequency Online UPS 10KVA-200KVA, Three Phase UPS

bargain

add to cart
Model NO. GP3310K-200K
Type On-line
Display LCD
Technology Mcu Control, IGBT
Specification CE, ISO9001
HS Code 8504402000
Phase Three Phase
Protection Short Circuit
Transformer Isolation Transformer
Trademark ZLPOWER
Origin Shenzhen, China
Intelligent Low frequency online UPS 10KVA-200KVA, Three phase UPS
Pure sine wave low frequency UPS
High speed MCU, IGBT technology
Application: Goverment, Building, Large computer room, Lab, and so on
Functions:
GP5300 series UPS is most advanced and new intelligent digital UPS by ZLPOWER. It is combined with high speed MCU, advanced CPLD technology, the sixth low consume large power, IGBT and static switch.
GP5300 series UPS have break the technology problems in stimulation circuit period. Digital control technology ensure that it can 100% apply to all kinds of grid environment, work with high stability. Each UPS capacity is from 10KVA to 400KVA, widely used in telecommunication, banks, negotiable securities, traffic, arms, security, electronics, industry, large enterprises and so on.
Products features:
1. Advanced digital circuit system
2. Intelligent management of batteries status
3. Intelligent inspect and monitor UPS systems every second
4. Intelligent communication tool remote control
5. The sixth generation IGBT inverter technology
6. High definition screen information management technology, humanity LCD display with Chinese and English, can show directly UPS status and operation, data records in table format, and events records, also can change language by main menu.
7. LED status shows operate steps and status directly.
8. GP5300 series UPS use touch screen with excellent ageing resistance function and case dealed with fluorin and carbon technology, lead it is environmental and durable; The UPS adopts knock-down modular design, ensure it easy to maintain and save resources much; It is with new advanced turbofan which can release heat well and save energy; It also use non-circumfluence controlled circuit, can save electric much; GP5300 UPS adopts green commute and inverter technology, ensure to provide clear energy for users; Its advanced digital circuit technology let whole UPS with 80% more life than before.
9. Excellent load characters can fulfill with suddenly change load from 0 to 100%, and no need to invert to bypass, ensure output stable and reliable.
10. Well-equipped protection function, including alarm function and excellent input and output Undervoltage overflow protection, input surge protection, phase failure protection, battery overcharge and over discharge protection, output overload short circuit protection, over heat protection and so on.
11. High quality active features, adopts instantaneous control method and virtual value response control and so on. This function realizes high active adjust and decrease output voltage degree of distortion.
12. Three phase can equal stable voltage and control separately, in order to control instantaneous overload degree of equal, realize output imbalance 100% load.
13. Optional input harmonic filter or Twelve-pulse rectifier, can restrain input harmonic pollution efficiently, improve UPS input power factor, and minish input harmonic current.
14. Optional battery inspection module, can test specification of every battery, and show on display. If battery faulty, will alarm immediately and notice administrators.
15. Special set: Can set UPS work status according to requirements of electric. User can choose from UPS operate mode, ECO save energy operate mode and EPS operate mode.
Model GP3310 ~ GP33200 series UPS
Capacity (VA) 10K 15K 20K 30K 40K 60K 80K 100K 120K 160K 200K
Noninal output capacity 8KW 12KW 16KW 24KW 32KW 48KW 64KW 80KW 96KW 128KW 160KW
Operate type Double conversion online type
Input voltage 220V/380, 230/400, 240/415V, ±25%usmn;25%usmn;25%
Phase Three phase +N+G
Frequency 50Hz/60Hz±5%lusmn;5%lusmn;5%
Input power factor 0.95(with input filter)
Soft start 0-100% 5sec
Output Voltage 220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load)5%(active load)5%(active load)
Phase Three phase +N+G
Frequency 50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode), Battery mode), Battery mode)
Power factor 0.8
Output wave Pure sine wave
Distortion Linear load <3%, non linear load<5%d<5%
Battery voltage Standard battery voltage 360V/384V
Floating charge 405V/432V
Terminal voltage 315V/336V
Charge current 1A-50A (Can calculate and set according to battery configuration software)
Maximum discharge current 28 42 56 85 113 169 225 282 338 381 507
Main Function Active voltage change 0-100%±5%lusmn;5%lusmn;5%
Instant recover time <10ms10ms
Imbalance voltage <±5%,<±1%( Balance load voltage)Balance load voltage)
Overload capacity 125%→10min,150%→1min%→1min;1min%→1min
Static switch Automatic
Protection UPS over current, short circuit, battery low voltage, over heat
Cold method Compel aeration ( temperature control mode)
Noise 60-65dB
Display LED; LCD display
Communication port(Optional) RS232, SNMP, dry-contact
Alarm Alarm with buzzer and indicators
Environment Temperature: 0-40C Humidity: 0-90%