Uninterrupted Power Supply, double conversion UPS 40-200kVA
No Breaks UPS 10kVA-200kVA
1.3phase+neutral+groud
2. High frequency
3. Digital LCD display, able to set voltage
4. IGBT technology
5. Bypass
6. Online, Double conversion
7. Operating battery: Lead acid battery
8. CE
UPS Key features:
1. Advanced digital circuit system
2. Intelligent management of batteries status
3. Intelligent inspect and monitor UPS systems every second
4. Intelligent communication tool remote control
5. The sixth generation IGBT inverter technology
6. High definition screen information management technology, humanity LCD display with Chinese and English, can show directly UPS status and operation, data records in table format, and events records, also can change language by main menu.
7. LED status shows operate steps and status directly.
8. GP5300 series UPS use touch screen with excellent ageing resistance function and case dealed with fluorin and carbon technology, lead it is environmental and durable; The UPS adopts knock-down modular design, ensure it easy to maintain and save resources much; It is with new advanced turbofan which can release heat well and save energy; It also use non-circumfluence controlled circuit, can save electric much; GP5300 UPS adopts green commute and inverter technology, ensure to provide clear energy for users; Its advanced digital circuit technology let whole UPS with 80% more life than before.
UPS Application: Telecommunication, banks, negotiable securities, traffic, arms, security, electronics, industry, large enterprises.
| Model | GP5310 ~ GP53200 series UPS | |
| Capacity(VA) | 10K | 15K | 20K | 30K | 40K | 60K | 80K | 100K | 120K | 160K | 200K |
| Noninal output capacity | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW |
| Operate type | Double conversion online type | |
| Input | voltage | 220V/380,230/400,240/415V,±25%usmn;25%usmn;25% | |
| Phase | Three phase +N+G | |
| Frequency | 50Hz/60Hz±5%lusmn;5%lusmn;5% | |
| Input power factor | 0.95(with input filter) | |
| Soft start | 0-100% 5sec | |
| Output | Voltage | 220V/380,230/400,240/415V,±1% (stable load) ,±5%(active load)5%(active load)5%(active load) | |
| Phase | Three phase +N+G | |
| Frequency | 50/60Hz (1±5%,AC mode),50/60Hz (±1%,Battery mode)%,Battery mode)%,Battery mode) | |
| Power factor | 0.8 | |
| Output wave | Pure sine wave | |
| Distortion | Linear load <3%, non linear load<5%d<5% | |
| Batteryvoltage | Standard battery voltage | 360V/384V | |
| Floating charge | 405V/432V | |
| Terminal voltage | 315V/336V | |
| Charge current | 1A-50A (Can calculate and set according to battery configuration software) | |
| Maximum discharge current | 28 | 42 | 56 | 85 | 113 | 169 | 225 | 282 | 338 | 381 | 507 |
| Main Function | Active voltage change | 0-100%±5%lusmn;5%lusmn;5% | |
| Instant recover time | <10ms10ms | |
| Imbalance voltage | <±5%,<±1%( Balance load voltage)Balance load voltage) | |
| Overload capacity | 125%→10min,150%→1min%→1min;1min%→1min | |
| Static switch | Automatic | |
| Protection | UPS over current, short circuit, battery low voltage, over heat | |
| Cold method | Compel aeration ( temperature control mode) | |
| Noise | 60-65dB | |
| Display | LED,LCD display | |
| Communicatin port(Optional) | RS232,SNMP,dry-contact | |
| Alarm | Alarm with buzzer and indicators | |
| Environment | Temperature 0~40cHumidity 0~90% | |