10-200kVA 3 Phase Online UPS Double Conversion UPS

10-200kVA 3 Phase Online UPS Double Conversion UPS

2250 USD

add to cart
Model NO. GP33 10-200kva
Type On-line
Application Industry
Standby Time Standard Machine
Output Capacity Large Type
Brand Zlpower
Power Range 8kVA to 160kw
Display LED or LCD Display
Battery Charge Current 1-50A
Output Wave Pure Sine Wave
Warranty 2 Years
Specification according to the inverter capacity
HS Code 8504402000
Phase Three Phase
Protection Unbalanced Loads
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Decentralized
Voltage Range 10kVA to 200kVA
Input/Output Phase Three Phase+N+G
Communication Port RS232,Snmp,Dry-Contact
Protection Level IP20
Protect UPS Over Current,Short Circuit,Battery Low Voltage
Trademark ZLPOWER
Origin Shenzhen, Guangdong

10-200KVA 3 Phase Online UPS Double Conversion UPS


1﹥ 8KVA to 200KVA, 8KW to 200KW three phase ,LED/LCD displayplay
2﹥ 400vac Input, 400vac Output,Pure Sine Wave outputtput
3﹥ 50/60hz Rated voltagetage
4﹥ IP20 Protection levelevel
5﹥ 0.8 power factorctor
6﹥ The sixth generation IGBT inverter technologylogy
7﹥ Adopts knock-down modular designsign
8﹥ Excellent load charactersters

Application

GP33 series low frequency Online UPS is most advanced and new intelligent digital UPS by ZLPOWER. It's widely used in telecommunication,data center,banks,negotiable securities,traffic,arms,security,electronics,industry,large enterprises and so on.
Product Introduction

Model GP3310 ~ GP33200 series Low Frequency Online UPS
Capacity (VA) 10K 15K 20K 30K 40K 60K 80K 100K 120K 160K 200K
Noninal output capacity 8KW 12KW 16KW 24KW 32KW 48KW 64KW 80KW 96KW 128KW 160KW
Operate type Double conversion low frequency online type
Input voltage 220V/380, 230/400, 240/415V, ±25%usmn;25%usmn;25%
Phase Three phase +N+G
Frequency 50Hz/60Hz±5%lusmn;5%lusmn;5%
Input power factor 0.95(with input filter)
Soft start 0-100% 5sec
Output Voltage 220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load)5%(active load)5%(active load)
Phase Three phase +N+G
Frequency 50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode), Battery mode), Battery mode)
Power factor 0.8
Output wave Pure sine wave
Distortion Linear load <3%, non linear load<5%d<5%
Battery voltage Standard battery voltage 360V/384V
Floating charge 405V/432V
Terminal voltage 315V/336V
Charge current 1A-50A (Can calculate and set according to battery configuration software)
Maximum discharge current 28 42 56 85 113 169 225 282 338 381 507
Main Function Active voltage change 0-100%±5%lusmn;5%lusmn;5%
Instant recover time <10ms10ms
Imbalance voltage <±5%,<±1%( Balance load voltage)Balance load voltage)
Overload capacity 125%→10min,150%→1min%→1min;1min%→1min
Static switch Automatic
Protection UPS over current, short circuit, battery low voltage, over heat
Cold method Compel aeration ( temperature control mode)
Noise 60-65dB
Display LED,LCD display
Communication port(Optional) RS232, SNMP, dry-contact
Alarm Alarm with buzzer and indicators
Environment Temperature: 0-40C Humidity: 0-90%
Net weight kgs 210 258 350 400 480 900 1100 1200 1250 1380 1520
Size L*W*H (mm) 700×520×110020×1100s;110020×1100 800×600×120000×1200s;120000×1200 800×600×150000×1500s;150000×1500 1200×900×160000×1600s;160000×1600

Product Details Show