1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS

1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS

100-800 USD

add to cart
Model NO. RA series
Type On-line
Application Remote Roads, Mountains, Bad Environment,
Standby Time Long-acting Machine
Output Capacity 1kVA-10kVA
Brand Zlpower
Nominal Voltage 220/230/240VAC
Frequency Range 50Hz:(46Hz~54Hz); 60Hz:(56Hz~6Hz)
DC Supply Voltage 36vdct96vdct96vdct240vdct240VDC
Communicate Interface RS232,Snmp Card(Optional)
Dimension 613X640X954mm
Specification 85KG-155KG/610*630*954mm
HS Code 8504402000
Phase Single Phase
Protection Short Circuit
Classification Power
Standby UPS Sine Wave Output UPS
Equipment Mode Decentralized
Product Name 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
Voltage Range 115~295VAC(±3VAC)/176~297VAC(±3VAC)AC(±3VAC);3VAC)AC(±3VAC)
Power Factor 0.98
Charge Current 4A/8A(Optional)/4.2A
Weight 85-155kg
Trademark as customer request
Origin China
Power Supply Outdoor UPS With 1 Hour Backup Outdoor UPS
Key Features
1.ZLPOWER Outdoor Intelligent High Frequency Online UPS provide continuous pure sine wave AC power supply for
outside communications / network equipment.
2.Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP65; With the wide range of input voltage and frequency of input window (- 45% +35% rated voltage and ± 10% rated frequency), in many remote areas of China after a severe test of the grid.he grid.he grid.
Application
This UPS is commonly used in the corner of the city, remote roads, mountains, bad environment, such as high temperature (+50 °C) / low temperature (-40 °C), severe dust, moisture, rain, mist erosion, very poor power quality (voltage longterm higher than 260V or less than 160V, frequency abnormal change) in the area.the area.the area.
High Reliability of the UPS System
1.Using microprocessor control, directly produce highfrequency pulse width modulation wave (SPWM) control of the UPS inverter, to simplify the UPS control circuit, to improve the stability, to have more real-time UPS to quickly respond to changes in the external environment and guarantee the machine's control circuit is more simple and reliable.
2.Using digital control techniques, to avoid the traditional analog control temperature drift inherent defects such as hardware parameters, to ensure consistency and reliability
of UPS.
PRODUCT SHOW




Product Descriptions of Outdoor UPS
Model RA outdoor UPS
1KVA 2KVA 3KVA 6KVA 10KVA
Capacity 1KVA/0.7KW 2KVA/1.4KW 3KVA/.1KW 6KVA/4.2KW 10KVA/7KW
Nominal Voltage 220/230/240VAC
Nominal Frequency 50HZ/60HZ
Input
Voltage Range 115~295VAC(±3VAC)mn;3VAC)mn;3VAC) 176~297VAC(±3VAC)mn;3VAC)mn;3VAC)
Frequency Range 50HZ:(46HZ~54HZ); 60HZ:(56HZ~6HZ)
Soft Start 0~100% 5sec
Power Factor 0.98
Output
Voltage Precision 223/230/240x(1±2%)usmn;2%)usmn;2%)
Frequency Precision 50/60HZ±0.05HZn;0.05HZn;0.05HZ
Power Factor 0.7/0.8(Optional) Standard 0.7
Wave Distortion Linear load<3% Non-linear<6%r<6%
Overload Capability Overload(110%~150%)for 30 seconds,then automatically transfer to bypass.when load is normal,it can automatically transfer to normal mode.
Crest Factor 3:1
Transfer Time 0MS(AC to DC)
Battery
DC Supply Voltage 36VDC 96VDC 96VDC 240VDC 240VDC
Charge Current 4A/8A(optional) 4A/8A(optional) 4A/8A(optional) 4.2A 4.2A
Internal Battery Caoacity (38/65/80/100AH)optional
Panel Displsy
LED Load level/Battery level,Battry indicator,Unility Power,Bypass,Overload,Fault
Communications
Communicate Interface RS232,SNMP Card(optional)
Work Environment
Temperature -40° C~50° C50° Cg; C50° C
Humidity 0~95%(Non-condensing)
Storage Temperature -25° C~55° C55° Cg; C55° C
Elevation <1500m
Physical Characterisstics
Weight(KG) N.W 85 125 125 150 155
Dimensions(WxDxH)mm 613x640x954 650x753x1227 650x753x1227 940x940x1770 940x940x1770