Double Conversion UPS 1kVA 2kVA 3kVA 6kVA 10kVA with 0ms Transfer Time

Double Conversion UPS 1kVA 2kVA 3kVA 6kVA 10kVA with 0ms Transfer Time

100-580 USD

add to cart
Model NO. GH11 1kva~10kva
Type On-line
Standby UPS Sine Wave Output UPS
Power Efficiency 0.8
Battery Type Sealed Lead Acid Maintenance-Free Battery
Warranty 12 Months
Transport Package Cartons
HS Code 8504402000
Phase Single Phase
Protection Short Circuit
Transfer Time 0 Ms
Battery Mode Standard Mode or External Battery Mode
Charging Period 4 Hours to 90% Capacity
Trademark STCB
Origin Guangzhou Shenzhen
Double Conversion UPS 1kVA 2kVA 3kVA 6kVA 10kVA with 0ms transfer time
Main Features:
1. True double-conversion
2. Microprocessor control optimizes reliability
3. Input power factor correction
4. Output power factor 0.8
5. Wide input voltage (110 v- 300 v)
6. Converter mode available
7. ECO mode for energy saving
8. Generator compatible
9. Charger capacity expansion to 6A for long-run models
10. Smart SNMP works well with either USB or RS-232 together
11. Comprehensive display allows easy monitoring and access of UPS status
Specification:
MODEL GH-1K (L) GH-2K (L) GH-3K (L)
CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W
INPUT
Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range 55-145 VAC or 110-300 VAC
Frequency Range 40Hz ~ 70 Hz
Power Factor ≥ 0.99 @ Nominal Voltage (100% load)oad)oad)
OUTPUT
Voltage Regulation 110v/220v ± 1%usmn; 1%usmn; 1%
Frequency Range 50 Hz or 60Hz ± 0.1 Hz; 0.1 Hz; 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤ 3 % THD (Linear Load)oad)oad)
≤ 6 % THD (Non-linear Load)oad)oad)
Transfer Time Zero
Waveform Pure Sinewave
EFFICIENCY
To AC Mode 88% 89% 90%
To Battery Mode 83% 87% 88%
BATTERY
Standard
Model
Battery Type 12 V /9 AH 12 V / 9AH 12 V / 9 AH
Numbers 2 4 6
Recharge Time 4 hours recover to 90% capacity
Charging Current 1.0 A
Long-run
Model
Battery Type Depending on the capacity of external batteries
Numbers 3 6 8
Charging Current 1.0A/2.0A/4.0A/6.0 A
PHYSICAL
Standard
Model
Dimension 285*145*220mm 395*145*240mm 415*190*337mm
Net Weight 9.3kg 18.6kg 30kg
Long-run Model Dimension 282*145* 220mm 397*145*220mm
Net Weight 4.6kg 6.8kg 7.4kg
MODEL GH11- 6K(L) GH11- 10K(L)
6000 VA / 4800 W 10000 VA / 8000 W
INPUT
Nominal Voltage 208/220/230/240VAC
Input voltage range 175V~290VAC ± 3%usmn; 3%usmn; 3%
Frequency Range 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz
Power Factor 0.99~1
OUTPUT
Nominal Voltage 208/220/230/240VAC ± 1%lusmn; 1%usmn; 1%
Frequency Range 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤3 % THD (Linear Load)oad)oad)
≤6 % THD (Non-linear Load)oad)oad)
Transfer Time Zero
Waveform Pure Sine wave
EFFICIENCY
Line Mode 89% 90%
Battery Mode 88% 89%
BATTERY
Standard Model Battery 12 V / 7 AH 12 V / 9 AH
Numbers 16 16
Recharge Time 9 hours recover to 90% capacity
Charging Current Default:1.0 A ± 10%,mn; 10%,mn; 10%,
Max.:2.0A ± 10%smn; 10%smn; 10%
Default:1.0 A ± 10%,mn; 10%,mn; 10%,
Max.:2.0A ± 10%usmn; 10%smn; 10%
Long-run Model Battery Depending on applications
Numbers 16/20pcs (adjustable)
Charging Current Default:4.0 A ± 10%,mn; 10%,mn; 10%,
Max.:6.0A ± 10%smn; 10%smn; 10%
Default:4.0 A ± 10%,mn; 10%,mn; 10%,
Max.:6.0A ± 10%smn; 10%smn; 10%
PHYSICAL
Standard Model Dimension 369*190*688mm 442*190*688mm
Net Weight 61kg 66kg
Long-run Model Dimension 369*190* 318mm 442*190* 318mm
Net Weight 12kg 16kg
* Product specifications are subject to change without further notice