Two-In-One Rack/Tower UPS, High Frequency Online UPS 1KVA-10KVA

Two-In-One Rack/Tower UPS, High Frequency Online UPS 1KVA-10KVA

499 USD

add to cart
Model NO. RT1K-RT10K
Type On-line
Two-In-One Tower/Rack Type
Technology IGBT
Height 2u, 3u, 6u
Transport Package Carton Package
Origin Shenzhen, China
Phase Single Phase
Protection Overvoltage
Capacity 1KVA-10KVA
Display LCD
Trademark ZLPOWER
Specification 2u, 3u, 6u
HS Code 8504402000
Two-in-One Rack/tower UPS, High frequency online UPS 1KVA-10KVA
RT1K, RT2K, RT3K: 2U height
RT6K: 3U height
RT10K: 6U height
Including Pedescal and rail kits.
IP/OP: 110/115/120VAC 50/60Hz
IP/OP: 220/230/240VAC 50/60Hz
Key Features
Microprocessor control guarantees high reliability
Rack Mount Design
Comprehensive self-protection design
Audible alarm mute
Cold start function
Auto self-testing system while turning on UPS
Wide input voltage range
Tower and rack mount UPS Model available
19-inch rack mount available, with 2U Height for UPS 1K-3KVA, 3U height for UPS 6KVA, 6U Height for UPS 10KVA
Excellent quality same as Santak, APC and Eaton UPS
With UPS SNMP Card Slot
Built Sealed lead acid, maintenance free UPS Battery Pack
LED/LCD Display
Can set nominal voltage, nominal frequency, and bypass voltage range via LCD panel key-press
Protection: Overload, Short Circuit, Overcurrent, Unbalanced Loads, Overvolta. Can solve power problems, such as: Power failure, power sags, high voltage spikes, switching transients, power surges, noise, frequency
Model TR1K TR1KL TR2K TR2KL TR3K TR3KL TR6KL
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W 6KVA/4200W
Input Voltage (115~300)VAC (176~276)VAC
Frequency 46~54Hz/56~64Hz (Adjustable via LCD panel)
Output Voltage 220/230/240(1±1%)VAC (Adjustable via LCD panel)D panel)D panel)
Frequency 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%)(1±0.2%)n;0.2%)(1±0.2%)
Output Wave Form Sine Wave
Back-up Time Full Load ≥5′e;5′prime;e;5′ Depends on the capacity of the external batteries bank ≥9′e;9′prime;e;9′ Depends on the capacity of the external batteries bank ≥5′e;5′prime;e;5′ Depends on the capacity of the external batteries bank Depends on the capacity of the external batteries bank
Half Load ≥14′;14′prime;;14′ ≥21′;21′prime;;21′ ≥15′;15′prime;;15′
Battery Nominal Voltage 36VDC 96VDC 240VDC
Transfer Time 0ms
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms 105%~130% 10min, over 150%1min
Communications RS-232+Intelligent Slot
Operating Environment Temperature 0C~40C
Humidity 15%~90%
Dimensions(W*D*H)mm 482.6*450*88 482.6*600*130
Net Weight(Kg) 16 9 10.5 11.5 11 12.5 19.5